MétaCan
Menu
Back to cohort
Record W1802956303 · doi:10.1111/jopr.12274

Assessment of the Internal Fit of Lithium Disilicate Crowns Using Micro‐CT

2015· article· en· W1802956303 on OpenAlexaff
David P. Alfaro, N. Dorin Ruse, Ricardo M. Carvalho, Chris Wyatt

Bibliographic record

VenueJournal of Prosthodontics · 2015
Typearticle
Languageen
FieldDentistry
TopicDental materials and restorations
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsMaterials scienceImpressionLithium disilicateCrown (dentistry)Cubic zirconiaComposite numberPost hocFabricationCeramicComposite materialDentistryComputer science

Abstract

fetched live from OpenAlex

PURPOSE: The aim of this study was to compare the internal fit of lithium disilicate crowns fabricated using digital technology with those fabricated by conventional means. MATERIALS AND METHODS: Forty-five lithium disilicate crowns were fabricated: 15 using digital impression and computer-aided design/computer-aided machining technique (group 1), 15 from the same digital impressions, but using a conventional die and laboratory fabrication process (group 2), and 15 using a conventional poly (vinyl siloxane) (PVS) impression and laboratory fabrication process (group 3). Tooth #15 was prepared for all-ceramic restoration on an ivorine typodont, which was digitized and a replica milled in zirconia to serve as master model. The master zirconia model was used for the impression procedures. Duplicate dies of the master zirconia die were made in polyurethane, enabling the internal fit of each crown to be evaluated using X-ray microcomputed tomography. The total volume of the internal space between the crown and die, the mean and maximum thickness of this space, and the percentage of the space that was at or below 120 μm thickness was calculated for each group and statistically tested for significant difference using one-way ANOVA, with post hoc Scheffé analysis. RESULTS: Group 1 crowns resulted in a smaller volume of internal space (12.49 ± 1.50 mm(3)) compared to group 2 (15.40 ± 2.59 mm(3) ) and to those of group 3 (18.01 ± 2.44 mm(3)). The mean thickness of the internal space for group 1 (0.16 ± 0.01 mm) and for group 2 (0.17 ± 0.03 mm) was significantly lower than that of group 3 (0.21 ± 0.03 mm). The average percentage of the internal space of a thickness of 120 μm and below was different between the three groups: 46.73 ± 5.66% for group 1, 37.08 ± 17.69% for group 2, and 22.89 ± 9.72% for group 3. Three-dimensional renderings of the internal space were also created. CONCLUSIONS: The results of this study suggested that pressed and milled IPS e. max crowns from LAVA COS digital impressions had a better internal fit to the prepared tooth than pressed IPS e.max crowns from PVS impressions in terms of total volume of internal space, average thickness of internal space, and percentage of internal space at or below 120 μm.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.091
GPT teacher head0.377
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations73
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueJournal of ProsthodonticsSame topicDental materials and restorationsFrench-language works237,207