MétaCan
Menu
Back to cohort
Record W1803930481 · doi:10.1016/j.ijcard.2015.09.023

Cardiac resynchronization therapy in chronic heart failure with moderately reduced left ventricular ejection fraction: Lessons from the Multicenter InSync Randomized Clinical Evaluation MIRACLE EF study

2015· article· en· W1803930481 on OpenAlexaff
Cecilia Linde, Anne B. Curtis, Gregg C. Fonarow, Kerry Lee, William C. Little, Anthony Tang, F Levya, Shin‐ichi Momomura, Christopher Manrodt, Tracy L. Bergemann, Martín Cowie

Bibliographic record

VenueInternational Journal of Cardiology · 2015
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsWestern University
Fundersnot available
KeywordsMedicineEjection fractionCardiac resynchronization therapyHeart failureClinical endpointCardiologyInternal medicineRandomized controlled trialQRS complexRandomizationClinical trialSurrogate endpoint

Abstract

fetched live from OpenAlex

BACKGROUND: The benefits of CRT for symptomatic heart failure (HF) patients with a wide QRS and reduced left ventricular ejection fraction (LVEF≤35%), are well established .Post-hoc subgroup analyses suggest that CRT benefit may extend to patients with LVEF>35%. METHODS: The MIRACLE EF was a prospective, randomized, controlled, double-blinded study to evaluate CRT-P in NYHA II-III HF patients with LBBB and with LVEF of 36%-50% and no previous pacing or ICD. The primary endpoint was a composite of time to first HF event or death. All patients were implanted with a CRT-P and randomized 2:1 to CRT-P ON or CRT-P OFF groups. The minimum follow up time was 24 months. RESULTS: The MIRACLE EF study was stopped for enrollment futility after 13 months and enrolling only 44 patients. The main difficulties in recruiting patients were lack of eligible patients, previous ICD implants, and the reluctance of institutions, patients or physicians to enroll in the study which included a potential 5 year CRT OFF period. CONCLUSION: Despite a careful design, identification and randomization of eligible patients were challenging and a trial to assess morbidity and mortality trial was not feasible. The MIRACLE EF experience illustrates the difficulties of designing a scientifically robust but feasible study to assess potential new indications for implantable devices. Smaller randomized studies with surrogate endpoints may therefore be more reasonable, although the potential impact of such studies on clinical practice, guidelines, and reimbursement remain to be determined.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.132
Threshold uncertainty score0.394

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.072
GPT teacher head0.410
Teacher spread0.338 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations33
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of CardiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207