MétaCan
Menu
Back to cohort

Rationale for using insensitive quality control rules for today’s hematology analyzers

2010· article· en· W1811109694 on OpenAlexaff
George S. Cembrowski, Bianca Smith, D.Y. Tung

Bibliographic record

VenueInternational Journal of Laboratory Hematology · 2010
Typearticle
Languageen
FieldMedicine
TopicClinical Laboratory Practices and Quality Control
Canadian institutionsUniversity of Alberta HospitalAlberta Hospital Edmonton
Fundersnot available
KeywordsHematology analyzerPercentileHematologyQuality (philosophy)Quality assuranceMedicineMedical physicsControl (management)StatisticsInstrumentation (computer programming)Computer scienceInternal medicineExternal quality assessmentMathematicsArtificial intelligencePathology

Abstract

fetched live from OpenAlex

Diverse approaches have been used to assure the analytical quality of automated hematology; as such, there is great variation in their error detection capabilities. We summarize the intralaboratory performance of a cohort of Sysmex XE-2100's running e-Check hematology quality control (QC). The imprecisions of a median performing (50th percentile imprecision) and more imprecise [15th percentile (15P) imprecision] Sysmex XE-2100 are compared with measures of total allowable error (regulatory and physiologically based) to obtain multiples of the usual imprecision that must be detected to prevent the hematology analyzer from producing medically unacceptable results. The resultant large multiples of the usual imprecision (s) demonstrate the need for insensitive QC rules employing very broad control ranges, control rules that have been implicitly supported by hematology analyzer manufacturers for the last several decades. For today's highly precise hematology analyzers, the following control rules are strongly advised: 1(3.5s) , 1(4s) and 1(4.5s) rules (violated if a single control observation exceeds either its ±3.5, ±4.0 and ±4.5s limits, respectively). In order for the hematology laboratory to totally embrace expanded QC limits, manufacturers must make available their instruments' usual and poorer (e.g. the 15P performance) imprecision's. Users of hematology analyzers that require more sensitive but less specific rules to prevent the reporting of clinically erroneous data are advised to acquire more precise (and thus more dependable) instrumentation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.239
metaresearch head score (Gemma)0.256
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.239
Threshold uncertainty score0.938

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.2390.256
Meta-epidemiology (narrow)0.0020.002
Meta-epidemiology (broad)0.0020.003
Bibliometrics0.0050.002
Science and technology studies0.0040.021
Scholarly communication0.0110.008
Open science0.0110.007
Research integrity0.0110.023
Insufficient payload (model declined to judge)0.0010.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.069
GPT teacher head0.443
Teacher spread0.375 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designNot applicable
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Laboratory HematologySame topicClinical Laboratory Practices and Quality ControlFrench-language works237,207