MétaCan
Menu
Back to cohort
Record W1826156929 · doi:10.1111/trf.13341

Introduction of a closed‐system cell processor for red blood cell washing: postimplementation monitoring of safety and efficacy

2015· article· en· W1826156929 on OpenAlexafffundabout
Jason P. Acker, Adele Hansen, Qilong Yi, Nayana Sondi, Christine Cserti‐Gazdewich, Jacob Pendergrast, Barbara Hannach

Bibliographic record

VenueTransfusion · 2015
Typearticle
Languageen
FieldMedicine
TopicBlood transfusion and management
Canadian institutionsUniversity Health NetworkUniversity of TorontoCanadian Blood ServicesUniversity of Alberta
FundersCanadian Blood Services
KeywordsMedicineAdverse effectHemoglobinRed blood cellClinical endpointBlood productBlood transfusionEmergency medicineAnesthesiaInternal medicineSurgeryClinical trial

Abstract

fetched live from OpenAlex

BACKGROUND: After introduction of a closed-system cell processor, the effect of this product change on safety, efficacy, and utilization of washed red blood cells (RBCs) was assessed. STUDY DESIGN AND METHODS: This study was a pre-/postimplementation observational study. Efficacy data were collected from sequentially transfused washed RBCs received as prophylactic therapy by β-thalassemia patients during a 3-month period before and after implementation of the Haemonetics ACP 215 closed-system processor. Before implementation, an open system (TerumoBCT COBE 2991) was used to wash RBCs. The primary endpoint for efficacy was a change in hemoglobin (Hb) concentration corrected for the duration between transfusions. The primary endpoint for safety was the frequency of adverse transfusion reactions (ATRs) in all washed RBCs provided by Canadian Blood Services to the transfusion service for 12 months before and after implementation. RESULTS: Data were analyzed from more than 300 RBCs transfused to 31 recipients before implementation and 29 recipients after implementation. The number of units transfused per episode reduced significantly after implementation, from a mean of 3.5 units to a mean of 3.1 units (p < 0.005). The corrected change in Hb concentration was not significantly different before and after implementation. ATRs occurred in 0.15% of transfusions both before and after implementation. CONCLUSION: Safety and efficacy of washed RBCs were not affected after introduction of a closed-system cell processor. The ACP 215 allowed for an extended expiry time, improving inventory management and overall utilization of washed RBCs. Transfusion of fewer RBCs per episode reduced exposure of recipients to allogeneic blood products while maintaining efficacy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.016
Threshold uncertainty score0.466

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.275
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2015
Admission routes3
Has abstractyes

Explore more

Same venueTransfusionSame topicBlood transfusion and managementFrench-language works237,207