Long‐Term Function of Single‐Implant Restorations: A 17‐ to 19‐Year Follow‐Up Study on Implant Infraposition Related to the Shape of the Face and Patients' Satisfaction
Bibliographic record
Abstract
BACKGROUND: Various levels of infraposition of single-implant restorations have been observed in long-term follow-up studies, but little knowledge is available on the biological mechanism behind this pattern. PURPOSE: The primary aim of this study is to report the frequency and severeness of implant infraposition in the anterior single-implant application after 17 to 19 years in function and, secondly, to try to relate these observations to anatomical appearance of the shape of the face of the patient. MATERIALS AND METHODS: The present study comprised of 57 patients who were provided with 65 CeraOne™ single-tooth restorations (Nobel Biocare AB, Gothenburg, Sweden) between 1989 and 1991. Altogether 46 of these patients were treated with single implants in the anterior region. Besides clinical and radiographic data, clinical photographs, study casts, and patient's assessment of the long-term aesthetic result (visual analog scale) was collected at the termination of the present study. The degree of implant crown infraposition was related to assessed facial shape and to patient and clinical assessment of the aesthetic result by means of Pearson's correlation test. To increase the numbers of patients, another group of 25 patients presented in another similar study were pooled with the present material for prevalence calculations. RESULTS: Altogether 47 patients showed up for the final examination after an average of 18 years (82%). Two implants failed (18 years cumulative survival rates [CSR]- 96.8%) and eight original single-crown restorations were replaced (CSR 83.8%). Three of the replaced crowns were replaced because of infraposition of the crowns. About 40% of the patients showed signs of infraposition, similar in younger and older age groups, but more frequently observed in female patients at termination of the study (p < 0.05). There was a weak trend indicating an association between "long-face" appearance and infraposition of the crown restoration (p > 0.05), and patients were more satisfied with the aesthetic clinical result than the participating clinicians (p < 0.05). CONCLUSION: Single-implant restorations in the anterior upper jaw may present small degrees of infraposition in long-term perspectives. Female patients seem to be at a higher risk of infraposition (p < 0.05), but no clear relationship between age at implant placement or facial shape and degree of infraposition was possible to establish (p > 0.05). Patients were more satisfied with the aesthetic result, as compared with the clinicians (p < 0.05), and patients seemed to pay less attention to the degree of infraposition in their aesthetic assessments, as compared with most of the clinicians.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".