MétaCan
Menu
Back to cohort
Record W1886982184 · doi:10.1186/s12891-015-0627-x

A scoping review of biomechanical testing for proximal humerus fracture implants

2015· review· en· W1886982184 on OpenAlexafffund
David W. Cruickshank, Kelly A. Lefaivre, Herman Johal, Norma J. MacIntyre, Sheila Sprague, Taryn Scott, Pierre Guy, Peter A. Cripton, Michael D. McKee, Mohit Bhandari, Gerard P. Slobogean

Bibliographic record

VenueBMC Musculoskeletal Disorders · 2015
Typereview
Languageen
FieldMedicine
TopicShoulder Injury and Treatment
Canadian institutionsUniversity of TorontoMcMaster UniversityUniversity of British Columbia
FundersCanadian Institutes of Health ResearchMcMaster University
KeywordsSports medicineMedicineOrthopedic surgeryHumerusRheumatologyFracture (geology)Humerus fractureProximal humerusRehabilitationBiomechanicsOrthodonticsPhysical therapySurgeryInternal medicineAnatomyEngineering

Abstract

fetched live from OpenAlex

BACKGROUND: Fixation failure is a relatively common sequela of surgical management of proximal humerus fractures (PHF). The purpose of this study is to understand the current state of the literature with regard to the biomechanical testing of proximal humerus fracture implants. METHODS: A scoping review of the proximal humerus fracture literature was performed, and studies testing the mechanical properties of a PHF treatment were included in this review. Descriptive statistics were used to summarize the characteristics and methods of the included studies. RESULTS: 1,051 proximal humerus fracture studies were reviewed; 67 studies met our inclusion criteria. The most common specimen used was cadaver bone (87%), followed by sawbones (7%) and animal bones (4%). A two-part fracture pattern was tested most frequently (68%), followed by three-part (23%), and four-part (8%). Implants tested included locking plates (52%), intramedullary devices (25%), and non-locking plates (25%). Hemi-arthroplasty was tested in 5 studies (7%), with no studies using reverse total shoulder arthroplasty (RTSA) implants. Torque was the most common mode of force applied (51%), followed by axial loading (45%), and cantilever bending (34%). Substantial testing diversity was observed across all studies. CONCLUSIONS: The biomechanical literature was found to be both diverse and heterogeneous. More complex fracture patterns and RTSA implants have not been adequately tested. These gaps in the current literature will need to be addressed to ensure that future biomechanical research is clinically relevant and capable of improving the outcomes of challenging proximal humerus fracture patterns.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.018
metaresearch head score (Gemma)0.067
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.037
Threshold uncertainty score0.093

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0180.067
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0050.005
Bibliometrics0.0370.027
Science and technology studies0.0020.002
Scholarly communication0.0050.003
Open science0.0030.002
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.101
GPT teacher head0.432
Teacher spread0.330 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueBMC Musculoskeletal DisordersSame topicShoulder Injury and TreatmentFrench-language works237,207