MétaCan
Menu
Back to cohort

In Vitro Measurements of Precision of Fit of Implant‐Supported Frameworks. A Comparison between “Virtual” and “Physical” Assessments of Fit Using Two Different Techniques of Measurements

2011· article· en· W1897730125 on OpenAlexvenueno aff
Torsten Jemt, Lars Hjalmarsson

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2011
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsScannerDistortion (music)Computer scienceImplantArtificial intelligenceMedicine

Abstract

fetched live from OpenAlex

BACKGROUND: Comparisons between different techniques measuring fit of implant-supported frameworks are few. PURPOSE: The purpose of this study was to compare data on precision of fit from two highly accurate measuring techniques and, also, to compare results using software programs for fit assessments considering both a "virtual" as well as a "physical" (i.e., more clinical) situation. MATERIALS AND METHODS: Five computer numerical control-milled titanium frameworks (Procera Implant Bridge, Nobel Biocare AB, Göteborg, Sweden) were fabricated from individual model/pattern measurements, simulating a clinical situation. Measurements of fit between frameworks and models were performed by means of a coordinate measuring machine (CMM; Zeiss Prismo Vast, Carl Zeiss Industrielle Messtechnik GmbH, Oberkochen, Germany) linked to a computer and an optical, high-resolution, three-dimensional scanner (Atos 4M SO, GOM International AG, Widen, Switzerland). Collected data on distortions between frameworks and models were analyzed and compared between the two measurement techniques. A comparison between "virtual" and "physical" fit assessments was also performed, based on data from the three-dimensional scanner. RESULTS: When using "virtual" fit assessment programs, overall mean three-dimensional distortion between implant and framework center points in absolute figures was 37 (SD 22) and 14 µm (SD 8) for the CMM and three-dimensional scanning measurements, respectively. Corresponding mean three-dimensional distortion when using a "physical" fit assessment program in the scanner was 43 µm (SD 24) (p < 0.001). Mean horizontal (x-axis) measurements of the distance between the two terminal implants of the models and the frameworks were 33.772 and 33.834 mm for the CMM technique. Corresponding measurements for the three-dimensional scanner was 33.798 and 33.806 mm, respectively. Horizontal distances from the three-dimensional scanner were, for most measurements, greater than for the CMM measurements. CONCLUSION: Measurements of fit between frameworks and models may vary depending on what technique is used and how fit assessments regarding "virtual" or "physical" fit is approached.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.024

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.013
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.452
GPT teacher head0.544
Teacher spread0.093 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations85
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207