MétaCan
Menu
Back to cohort
Record W1915640804 · doi:10.1109/nssmic.1995.500254

Initial results from the Sherbrooke avalanche photodiode PET scanner

2002· article· en· W1915640804 on OpenAlexaffabout
Roger Lecomte, J. Cadorette, S. Rodrigue, D. Lapointe, D. Rouleau, M’hamed Bentourkia, Rutao Yao, P. Msaki, G. Schmutz

Bibliographic record

Venue1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record · 2002
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversité de Sherbrooke
Fundersnot available
KeywordsAvalanche photodiodeScannerImaging phantomImage resolutionPhotodiodeDetectorSensitivity (control systems)Positron emission tomographyComputer scienceBiomedical engineeringMaterials scienceOpticsNuclear medicinePhysicsMedicineEngineeringElectronic engineering

Abstract

fetched live from OpenAlex

The design features and engineering constraints of a PET system based on avalanche photodiode (APD) detectors have been described in a previous report. Here, the authors present the initial results obtained with the Sherbrooke APD-PET scanner, a very high spatial resolution device designed for dynamic imaging of small and medium-sized laboratory animals such as rats, cats, rabbits and small monkeys. Its physical performance have been evaluated in terms of resolution, sensitivity, count rate, random and scatter fractions, and activity recovery as a function of object size. The capabilities of the scanner for biomedical research applications have been demonstrated using phantom and animal studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesScience and technology studies, Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.637
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0010.003
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.294
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2002
Admission routes2
Has abstractyes

Explore more

Same venue1995 IEEE Nuclear Science Symposium and Medical Imaging Conference RecordSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207