MétaCan
Menu
← Back to cohort
Record W19354382 · doi:10.1121/1.3081392

Techno-Economic Analysis of Heat Pump and Cogeneration Systems for a High Performance Midrise Apartment in the Canadian Climate

2014· article· en· W19354382 on OpenAlexaboutno aff
Martin Kegel, Justin Tamasauskas, Roberto Sunyé, Daniel J. Giguere

Bibliographic record

VenueThe Journal of the Acoustical Society of America · 2014
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsnot available
Fundersnot available
KeywordsCogenerationHeat pumpTRNSYSAir source heat pumpsPrimary energyHeating systemBoiler (water heating)EngineeringElectricityEnvironmental scienceCoefficient of performanceWaste managementGreenhouse gasElectricity generationMechanical engineeringMeteorologyElectrical engineeringThermal

Abstract

fetched live from OpenAlex

With increased awareness on the importance and benefit of energy efficiency, building owners and designers are frequently confronted with the challenge of which mechanical system is most suitable to meet the building’s energy target needs. The decision making process is often aided through the use of building simulation tools; however this type of analysis is often considered costly and time consuming in particular when various mechanical systems need to be assessed. With Natural Resources Canada’s priorities on promoting the sustainability and economic development of Canada’s natural resources, this paper presents an analysis conducted on several standard and innovative mechanical systems to aid decision makers in the early building design stages to select a suitable system. The paper further illustrates the benefits of each system type often not known or misunderstood. Using TRNSYS, five system types are evaluated in a typical newly constructed high performance mid-rise apartment in two Canadian regions: Calgary and Montreal. The five systems selected for comparison include (1) a conventional mid-rise apartment heating and cooling system, (2) boiler/cooling tower water source heat pumps, (3) ground source heat pumps, (4) a cogeneration unit sized to meet the heating load of the building and (5) a cogeneration plus electric driven heat pump system. Heat pumps were selected for the benefit in upgrading and utilizing renewable energy sources and cogeneration for the conversion of natural gas to electricity. The analysis includes a 20 year life cycle cost including a sensitivity analysis on forecasted utility rates.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.487
Threshold uncertainty score0.980

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0020.002
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.193
Teacher spread0.187 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of the Acoustical Society of America→Same topicBuilding Energy and Comfort Optimization→French-language works237,207→