MétaCan
Menu
Back to cohort
Record W1951997664 · doi:10.1111/hdi.12206

Can primary failure of arteriovenous fistulas be anticipated?

2014· article· en· W1951997664 on OpenAlexvenueno aff
Dilek Gibyeli Genek, Canan Altay, Tarkan Ünek, Aykut Sifil, Mustafa Seçil, Taner Çamsarı

Bibliographic record

VenueHemodialysis International · 2014
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineBrachial arteryCephalic veinArteriovenous fistulaHemodialysisCardiologyFistulaThrombosisInternal medicineSurgeryStage (stratigraphy)Radial arteryArteryVeinBlood pressure

Abstract

fetched live from OpenAlex

Primary failure, early thrombosis, and inadequate maturation are the main complications encountered in arteriovenous fistulas. Doppler ultrasonographic assessment of flow-mediated dilatation (FMD) is currently used for the early diagnosis of atherosclerosis. Clinical experience in the use of FMD for preoperative assessment of vasculature is rather limited; therefore, we sought to elucidate the relationship between preoperative FMD and primary failure of the fistula. Thirty-three patients with end-stage renal disease who were admitted to our hospital between January and July 2005 were included in our study. Medical histories were established and the internal diameter, wall thickness, peak systolic flow rate, and resistive index (RI) were measured in the cephalic vein and radial and brachial arteries. Flow-mediated dilatation and nitrate-mediated dilatation (NMD) of the brachial artery were assessed. Fistulas were evaluated 48 hours and 30 days postoperatively. Brachial arterial internal diameter was lower in all fistulas that developed primary failure in 48 hours (0.4 ± 0.07 cm vs. 0.35 ± 0.07 cm, P = 0.016). The radial artery RI was found to be significantly elevated in fistulas with both early (48-hour) and late-term (30-day) failure (0.9 ± 0.08 vs. 0.68 ± 0.3, P = 0.01, and 0.86 ± 0.8 vs. 0.67 ± 0.3, P = 0.038, respectively). The brachial artery peak systolic flow rate was significantly reduced in patients in the radiocephalic fistula group that developed early and late-term failure (42.9 ± 12 cm/sec vs. 68.4 ± 10 cm/sec, P = 0.01, and 44.1 ± 13 cm/sec vs. 57.7 ± 16 cm/sec, P = 0.038, respectively). Our study, constrained by a smaller, older patient group, was unable to show a statistically significant correlation between FMD, NMD, and fistula success. Any single parameter may not be sufficient to assess vascular health preoperatively. A multifactorial approach incorporating parameters evaluating arterial and venous function might be more effective in predicting fistula success. Further studies on larger patient groups may indeed demonstrate the value of these assessments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.010
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.323
Teacher spread0.293 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207