MétaCan
Menu
Back to cohort
Record W195332732 · doi:10.5144/0256-4947.2000.398

Partial Correction of Cobb Angle Prior to Posterior Spinal Instrumentation

2000· article· en· W195332732 on OpenAlexaff
Yaser M Behairy, Diana L. Hauser, Douglas L. Hill, James Mahood, Marc Moreau

Bibliographic record

VenueAnnals of Saudi Medicine · 2000
Typearticle
Languageen
FieldMedicine
TopicScoliosis diagnosis and treatment
Canadian institutionsUniversity of AlbertaGlenrose Rehabilitation Hospital
Fundersnot available
KeywordsMedicineCobBInstrumentation (computer programming)Orthopedic surgeryMedical schoolCobb angleLibrary scienceMedical physicsGeneral surgerySurgeryScoliosisMedical educationComputer science

Abstract

fetched live from OpenAlex

BACKGROUND: A substantial contribution to the overall surgical correction of Cobb angle has been observed to occur prior to securing the instrumentation. Knowledge specific to the amount of correction prior to instrumentation is scarce in the medical literature. If significant correction is due to the positioning and muscle stripping during exposure of the spine, questions arise about the usefulness and need for extensive rod-rotation maneuvers to further straighten the spine. This study quantifies the extent of correction achieved from standing to prone, with the spine exposed before and after instrumentation. MATERIALS AND METHODS: Eleven patients with the diagnosis of adolescent idiopathic scoliosis (AIS) and a right thoracic major curve were included in the study. Intraoperative changes in Cobb angle were measured before and after instrumentation, as well as postoperatively. The patients underwent posterior spinal instrumentation by the same surgical team using the rod-rotation techniques. Radiographs were taken prior to surgery, intraoperatively before and after instrumentation and postoperatively within one week from surgery. Cobb angle measurements were performed by the same examiner. RESULTS: The median preoperative Cobb angle of 60 degrees +/-14 degrees (48-90 degrees ) corrected to a median of 26 degrees +/-22 degrees (10-80 degrees ) on the right bend film, to a median of 55 degrees +/-12 degrees (30-70 degrees ) intraoperatively after exposure, and to a median 30 degrees +/-10 degrees (20-46 degrees ) after rod-rotation/instrumentation and fixation. The follow-up standing radiograph median Cobb angle was 40 degrees +/-14 degrees (9-56 degrees ). A median intraoperative correction of 28 degrees was obtained, 10 degrees of which was prior to the rod rotation and instrumentation. High variability was observed in the percentage contribution of pre-instrumentation release with a median of 42%+/-25% (0-67%). CONCLUSION: Approximately one-third of the total correction occurred prior to instrumentation being applied, and even though it was variable and substantial, the actual surgical rod rotation and instrumentation maneuver provided the majority of correction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.880
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.068
GPT teacher head0.380
Teacher spread0.312 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueAnnals of Saudi MedicineSame topicScoliosis diagnosis and treatmentFrench-language works237,207