MétaCan
Menu
← Back to cohort
Record W1964442605 · doi:10.1118/1.4814994

SU-E-T-565: Fast Dose Kernel Interpolation Using Fourier Transform with Application to Permanent Prostate Brachytherapy

2013· article· en· W1964442605 on OpenAlexaffabout
D Liu, Ron S. Sloboda

Bibliographic record

VenueMedical Physics · 2013
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsMathematicsKernel (algebra)Interpolation (computer graphics)AlgorithmFourier transformBrachytherapyFast Fourier transformComputer scienceMathematical analysisRadiation therapyArtificial intelligenceMedicineDiscrete mathematics

Abstract

fetched live from OpenAlex

Purpose: The Fourier transform (FT) method by Boyer for seed implant dose calculation (Med Phys 1986; 13:525–29) requires that seeds be placed at calculation grid points. This abstract proposes an additional interpolation step enabling arbitrary seed placement while preserving the computational efficiency of the original method. Methods: The TG-43 dose kernel for an Iodine-125 seed was sampled on a 3-D grid with 1 mm spacing. For each seed, the kernel was shifted to the nearest grid point via a unit impulse convolution. For the remaining fractional shift, the proposed method added a piece-wise 3rd order Lagrange interpolating filter. An additional least-square filter optimized interpolation accuracy for the clinically relevant dose range below 300 Gy at the expense of higher doses. The convolution operations were implemented in the Fourier domain. Results for the proposed interpolating FT method were compared to the original FT method and to TG-43 calculations. Interpolation accuracy for a single seed was evaluated by up-sampling and interpolating the dose kernel. Pre-and post-treatment plans were calculated for 10 patients. Results: The interpolation error for the single seed kernel was 1 % at 5 mm distance (original method error was 20 %). Treatment plan point dose error was within 2 % for doses under 300 Gy. The dose-volume histogram error was negligible. Computation times for the original and interpolating FT methods were independent of the number of seeds. The addition of the interpolation step did not affect the computation time. Conclusion: The FT method of Boyer was expanded to include an interpolation step, thereby relaxing the original restriction that seeds be placed at calculation grid points. The proposed interpolating method calculated treatment plans within 2 % accuracy for a clinically relevant dose range. The computational efficiency of the original method was preserved with negligible increase in computation time. This work was supported by a Canada Graduate Scholarships doctoral award provided by the Canadian Institutes of Health Research (#226291)

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.274
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→