MétaCan
Menu
← Back to cohort
Record W1965062675 · doi:10.1118/1.3468758

SU‐GG‐T‐361: Feasibility of Making In‐Vivo Peripheral Dose Measurements Using a Portable Dosimeter System ‐ Beta Testing of a Novel Device

2010· article· en· W1965062675 on OpenAlexaboutno aff
Shirish Jani, Nalini Shah

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsnot available
Fundersnot available
KeywordsDosimeterReproducibilityNuclear medicineDosimetryIonization chamberDose profileCalibrationMedicineMaterials scienceBiomedical engineeringPhysicsMathematicsIonStatistics

Abstract

fetched live from OpenAlex

Purpose: Peripheral Dose (PD) to structures such as testes, thyroid, or contra‐lateral breast has important clinical implications regarding the health of a patient. The purpose of this study was to determine utility of a new Portable Dosimeter System for PD measurements to critical structures outside of radiation fields. Method and Materials: Measurements were made using a pair of Portable Dosimeters, Model TN‐RD‐90 (Best Medical Canada Ltd.) At the time of the study, the device was going through the FDA approval process and this study was part of beta testing in a community hospital environment. The dosimeters were calibrated at high sensitivity of 3 mV/cGy as opposed to standard sensitivity of about 1 mV/cGy. Reproducibility and linearity of dose response were tested from a low dose range of 1–50 cGy. Peripheral dose measurements were made using solid water phantoms (100cm SSD; 10cm × 10cm field) on a 6MV (Novalis) and a 6/18 MV linac (Clinac‐2100EX) and compared them to ion chamber values. Results: Calibration of dosimeters showed both to have 3mV/cGy response. These MOSFETs were able to read a dose of 50 cGy or less with over 95% accuracy. Their dose linearity was excellent; R‐sq value was near 1 for both. Accuracy of dose readout decreased with lower dose values. At 1 cGy, the error was about 10% when averaged over 2 dosimeters. At a dose level of 0.25 cGy, the dosimeters' reproducibility and accuracy suffered. However, even with a 50% uncertainty in measured dose, the absolute dose derived was still clinically useful. Conclusion: The new mosfet dosimeters were easy to use, linear in response and reproducible. They will be clinically useful for in‐vivo dosimetry.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.087
GPT teacher head0.350
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→