MétaCan
Menu
Back to cohort
Record W1966355562 · doi:10.1093/rpd/nci676

Comparison of the energy-response factor of LiF and Al2O3 in radiotherapy beams

2006· article· en· W1966355562 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueRadiation Protection Dosimetry · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsFoothills Medical Centre
Fundersnot available
KeywordsMonte Carlo methodLithium fluorideGamma rayIrradiationPhotonPhysicsRange (aeronautics)OpticsBeam (structure)RadiationMaterials scienceImaging phantomNuclear physics

Abstract

fetched live from OpenAlex

A Monte Carlo study of the energy-response factor of aluminium oxide (Al2O3) and lithium fluoride (LiF) TLDs in kilovoltage and megavoltage photon beams relative to 60Co gamma rays has been performed using EGSnrc Monte Carlo simulations. The sensitive volume of the detector was simulated as a disc of diameter 2.85 mm and thickness 1 mm. The phantom material was water and the irradiation depth was 2.0 cm in kilovoltage photon beams and 5.0 cm for megavoltage photon beams. The results show that the energy-response of the Al2O3 and LiF-TLDs is constant within 3% for photon beam energies in the energy range of 60Co gamma rays to 25 MV X rays. However, both detectors show an enhanced response for kilovoltage photon beams, which in the case of 50 kV X rays is 3.2 times higher than that for 60Co gamma rays. The energy-response factor was 1.46 for LiF irradiated in 50 kV X rays. The Al2O3 detector has an energy-response that is 2.2 times higher than that of LiF in 50 kV X rays decreasing to 1.19 for 250 kV X rays. The results show that the addition of 0.1 or 1% of carbon by weight (as dopant) into the Al2O3 does not change the Monte Carlo determined energy-response factor by more than 1%.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.340
Threshold uncertainty score0.332

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.281
Teacher spread0.273 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it