MétaCan
Menu
Back to cohort
Record W1967016724 · doi:10.1121/1.4899538

Temperature dependence of harmonics generated by nonlinear ultrasound beam propagation in water

2014· article· en· W1967016724 on OpenAlexaff
B. Maraghechi, Michael C. Kolios, Jahangir Tavakkoli

Bibliographic record

VenueThe Journal of the Acoustical Society of America · 2014
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsHydrophoneHarmonicsAcousticsUltrasoundMaterials scienceHarmonicAmplitudeTransducerSound pressureNonlinear systemPhysicsOptics

Abstract

fetched live from OpenAlex

Ultrasound thermal therapy is used for noninvasive treatment of cancer. For accurate ultrasound based temperature monitoring in thermal therapy, the temperature dependence of acoustic parameters is required. In this study, the temperature dependence of acoustic harmonics was investigated in water. The pressure amplitudes of the transmitted fundamental frequency (p1), and its harmonics (second (p2), third (p3), fourth (p4), and fifth (p5)) generated by nonlinear ultrasound propagation were measured by a calibrated hydrophone in water. The hydrophone was placed at the focal point of a focused 5-MHz transducer (f-number 4.5) to measure the acoustic pressure. Higher harmonics were generated by transmitting a 5-MHz 15-cycle pulse that resulted in a focal positive peak pressure of approximately 0.26 MPa in water. The water temperature was increased from 26 °C to 52 °C in increments of 2 °C. Due to this temperature elevation, the value of p1 decreased by 9%±1.5% (compared to its value at 26 °C) and values of p2, p3, p4, and p5 increased by %5±2%, 22%±8%, 44%±7%, and 55%±5%, respectively. The results indicate that the nonlinear harmonics are highly temperature dependent and their temperature sensitivity increase with the harmonic number. It is concluded that the nonlinear harmonics could potentially be used for ultrasound-based thermometry.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.201
Teacher spread0.196 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of the Acoustical Society of AmericaSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207