MétaCan
Menu
Back to cohort
Record W1967816620 · doi:10.1002/mrm.21582

Rapid and efficient mapping of regional ventilation in the rat lung using hyperpolarized <sup>3</sup>He with Flip angle variation for offset of RF and relaxation (FAVOR)

2008· article· en· W1967816620 on OpenAlexaff
Giles Santyr, Wilfred Lam, Alexei Ouriadov

Bibliographic record

VenueMagnetic Resonance in Medicine · 2008
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAtomic and Subatomic Physics Research
Canadian institutionsRobarts Clinical TrialsWestern University
Fundersnot available
KeywordsFlip angleVentilation (architecture)Offset (computer science)Relaxation (psychology)HeliumLung ventilationLungNuclear magnetic resonanceNuclear medicineMaterials sciencePhysicsBiomedical engineeringChemistryMedicineMagnetic resonance imagingAtomic physicsComputer scienceInternal medicineRadiology

Abstract

fetched live from OpenAlex

A novel imaging method is presented, Flip Angle Variation for Offset of RF and Relaxation (FAVOR), for rapid and efficient measurement of rat lung ventilation using hyperpolarized helium-3 (3He) gas. The FAVOR technique utilizes variable flip angles to remove the cumulative effect of RF pulses and T1 relaxation on the hyperpolarized gas signal and thereby eliminates the need for intervening air wash-out breaths and multiple cycles of 3He wash-in breaths before each image. The former allows an improvement in speed (by a factor of approximately 30) while the latter reduces the cost of each measurement (by a factor of approximately 5). The FAVOR and conventional ventilation methods were performed on six healthy male Brown Norway rats (190-270 g). Lobar measurements of ventilation, r, obtained with the FAVOR method were not significantly different from those obtained with the conventional method for the right middle and caudal and left lobes (P>0.05 by a Wilcoxon matched pairs test). A methacholine challenge test was also administered to an animal and reduction and recovery of r was detected by the FAVOR method. The reduced 3He consumption and the improvement in speed provided by FAVOR suggest that it may allow measurement of ventilation in human subjects not previously possible.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.268
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations45
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAtomic and Subatomic Physics ResearchFrench-language works237,207