MétaCan
Menu
Back to cohort
Record W1967915736 · doi:10.1118/1.2241934

TH‐E‐330A‐02: A Local Fourier Description of Artifacts in Circular Cone Beam Computed Tomography

2006· article· en· W1967915736 on OpenAlexaff
S Bartolac, Frédéric Noo, Rolf Clackdoyle, D Moseley, Jeffrey H. Siewerdsen, David A. Jaffray

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsImaging phantomCone beam computed tomographyIterative reconstructionFourier transformVoxelRadon transformOpticsFrequency domainPhysicsSpatial frequencyMathematicsComputer visionComputed tomographyMathematical analysisComputer science

Abstract

fetched live from OpenAlex

Purpose: Circular cone‐beam computed tomography is challenged by a lack of plane sums resulting in incomplete inversion of the radon transform. These missing plane sums have been identified by theory, and may be represented as a shift‐variant cone of missing frequencies in the Fourier domain. The aim was to verify the presence of this cone in real data, and to show the dependency of resulting image artifacts on the frequency distribution of the imaged object. Method and Materials: A mini disk phantom (mylar/foam) was constructed to probe the local frequency response at various locations in the reconstruction space. Projections obtained using an experimental CBCT benchtop were reconstructed with 120 μm3 voxel size using a modified Feldkamp filtered backprojection routine. Local Fourier transforms of the mini disks were analyzed for missing frequency data and compared with theory. Large disk phantoms of acrylic and cellular polyurethane were also imaged for further demonstration of the effect of varying the frequency content of the imaged object. Results: The cone of missing frequency was successfully identified in the mini disk phantom and agreed well with theory. Image artifact was found to have dependency on the local distribution of the object's frequency power spectrum relative to the cone of missing frequency information. Decreased resolution of the disks occurred when their dominant spatial frequency components were directionally aligned to coincide with the predicted null cone, as expected. Image reconstructions of large disk phantoms showed good detail in cellular disks even at locations that showed strong artifacts in the acrylic disk. Conclusion: The predicted null cone is observable in Fourier transforms of localized objects. Resolution in reconstruction is dependent on the relative frequency distribution of the imaged object; features that are most poorly resolved will be those with strong frequency components directed in the expected null space.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.271
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207