MétaCan
Menu
Back to cohort
Record W1968076397 · doi:10.1366/0003702001948169

Use of Laser Light Scatter Signals to Study the Effect of a Direct-Current Biased Mesh Screen in a Spray Chamber on Aerosols Generated for Use in Atomic Spectroscopy

2000· article· en· W1968076397 on OpenAlexaff
Qiang Xu, George R. Agnes

Bibliographic record

VenueApplied Spectroscopy · 2000
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsSimon Fraser University
Fundersnot available
KeywordsAerosolChemistryLaserInductively coupled plasmaSIGNAL (programming language)PlasmaAnalytical Chemistry (journal)SpectroscopyIonizationOpticsIonPhysicsNuclear physics

Abstract

fetched live from OpenAlex

A new method that relies on tertiary aerosol laser light scatter signals to alleviate the NaCl chemical matrix effect in inductively coupled plasma atomic emission spectroscopy (ICP-AES) is introduced. The method involves monitoring the laser light scatter signal from the entire tertiary aerosol with a line-shaped laser beam and the plasma off. In this work, the tertiary aerosol laser scatter signal was measured to increase nonlinearly with NaCl concentration. The source of the increased scatter signal is described as originating from Coulomb fission events that droplets with net charge experience while inside the spray chamber. Each droplet in the secondary aerosol that undergoes Coulomb fission introduces ∼ 20 progeny droplets into the aerosol stream. The introduction of progeny droplets to the aerosol stream measured by increased laser light scatter signals coincides with an increase in analyte emission, off-axis, at low viewing heights in an inductively coupled plasma, a characteristic of the easily ionized element chemical matrix effect. It is shown that a direct-current potential applied to a mesh screen positioned inside the spray chamber can coarsely control the transport of droplets with net charge through the spray chamber, by effecting their removal from the aerosol stream. With an appropriate voltage applied to the mesh, the laser scatter signal from the tertiary aerosol from a solution containing 100 mM NaCl can be made similar to the scatter signal from a solution that does not contain NaCl. Under the same conditions, calcium-ion lateral emission signal intensity contour maps in a plasma for the same two solutions become similar within the normal analytical zone in the plasma (2 mm wide, from 13 to 19 mm above the load coil).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.016
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.299
Teacher spread0.274 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueApplied SpectroscopySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207