MétaCan
Menu
Back to cohort
Record W1968820880 · doi:10.1118/1.3181445

SU‐FF‐J‐152: Dosimetry On Gold Nanoparticle: A Microscopic and Macroscopic Study Using Monte Carlo Simulations

2009· article· en· W1968820880 on OpenAlexaff
James C. L. Chow, M. Leung, Devika B. Chithrani, M Lee, B Oms, David A. Jaffray

Bibliographic record

VenueMedical Physics · 2009
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsMonte Carlo methodColloidal goldPhotonDosimetryPhotoelectric effectIrradiationPhoton energyBeam (structure)Materials scienceNanoparticlePhysicsAtomic physicsOpticsNuclear physicsNuclear medicineNanotechnologyMedicine

Abstract

fetched live from OpenAlex

Purpose: This study investigated dosimetric characteristics of gold nanoparticle under a photon beam. A single gold nanoparticle (microscopic) and a mixture of gold and water (macroscopic) were considered using Monte Carlo simulations based on the Geant4‐ and EGSnrc‐based code, respectively. Methods and Materials: A single gold nanoparticle (diameter of 100 nm) was irradiated by photon beams with energies of 35.5keV, 73.3keV, 660keV, 1.2MeV and 6MeV in water. 250 million histories were used in Monte Carlo simulation to record different numbers of interactions ( e.g. photoelectric and Compton) with and without the gold nanoparticle in water. Moreover, a mixture of gold and water was irradiated with photon beams. The dose enhancement ratios (dose of gold and water mixture/dose of water) were determined with different photon beam energies and concentrations of gold. Results: With a single gold nanoparticle, the number of photoelectric interaction was about 47 times larger than that of Compton for the 35.5keV photon beams. This was opposite to the 6MeV photon beams, where the number of Compton interaction was about 46.5 times larger than that of the photoelectric. Although the values of ratio were similar, the total number of interactions for the 35.5keV photon beams was in fact 348 times larger than that of the 6MeV. A larger energy deposition was therefore found when the photon beam energy was decreased from the MeV to keV range. This result agreed with that from a gold and water mixture. Moreover, increasing the concentration of gold increased the dose enhancement in water. Conclusions: Both microscopic and macroscopic study on gold nanoparticle agree that more energy deposition is found when the photon beam energy is decreased from MeV to keV range, due to the increase of photoelectric interaction. A higher concentration of gold can increase the dose enhancement in water.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.161
Threshold uncertainty score0.646

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.336
Teacher spread0.312 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Therapy and DosimetryFrench-language works237,207