MétaCan
Menu
Back to cohort
Record W1969996168 · doi:10.1117/12.536863

Indirect flat-panel detector with avalanche gain

2004· article· en· W1969996168 on OpenAlexaff
Wei Zhao, Dylan Hunt, Kenkichi Tanioka, J. A. Rowlands

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2004
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsSunnybrook Health Science Centre
FundersNational Institutes of Health
KeywordsAvalanche photodiodeOpticsDetectorAvalanche diodePhysicsDetective quantum efficiencyScintillatorElectron avalancheSingle-photon avalanche diodeFlat panel detectorNoise (video)PhotomultiplierAvalanche breakdownScintillationOptoelectronicsParticle detectorPhoton countingVoltageBreakdown voltageComputer scienceIonization

Abstract

fetched live from OpenAlex

A new concept - an indirect flat-panel detector with avalanche gain - for low dose x-ray imaging has been proposed. The detector consists of an amorphous selenium (a-Se) photoconductor optically coupled to a structured cesium iodide (CsI) scintillator. Under an electric field E<sub>Se</sub>, the a-Se is sensitive to light and converts the optical photons emitted from CsI into electronic signal. These signals can be stored and read out in the same fashion as in existing flat-panel detectors. When E<sub>Se</sub> is increased to > 90 V/&mu;m, avalanche multiplication occurs. The avalanche gain ranges between 1-800 depending on E<sub>Se</sub> and the thickness of the a-Se layer d<sub>Se</sub>. The avalanche a-Se photoconductor is referred to as HARP (High-gain Avalanche Rushing amorphous Photoconductor). A cascaded linear system model for the proposed detector was developed in order to determine the optimal CsI properties and avalanche gain for different x-ray imaging applications. Our results showed that x-ray quantum noise limited performance can be achieved at the lowest exposure level necessary for fluoroscopy (0.1 &mu;R) and mammography (0.1 mR) with a moderate avalanche gain of 20 (d = 1-2 &mu;m). A laboratory test system using an existing HARP tube optically coupled (through a lens) to a CsI layer was built and the advantage of avalanche gain in overcoming electronic noise was demonstrated experimentally. One of the advantages of the avalanche gain is that it will permit the use of high resolution (HR) CsI (which due to its low light output has not previously been used in flat-panel detectors) to improve DQE at high spatial frequencies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.203
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.221
Teacher spread0.209 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicDigital Radiography and Breast ImagingFrench-language works237,207