MétaCan
Menu
Back to cohort

Bioreactance: A new tool for cardiac output and thoracic fluid content monitoring during hemodialysis

2009· article· en· W1970633711 on OpenAlexvenueno aff
Niloufar Kossari, Gilles Hufnagel, Pierre Squara

Bibliographic record

VenueHemodialysis International · 2009
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineHemodialysisCardiologyHematocritInternal medicineCardiac outputHemodynamicsNuclear medicine

Abstract

fetched live from OpenAlex

Outpatient hemodialysis therapy (HD) can be associated with hemodynamic compromise. Bioreactance has recently been shown to provide accurate, noninvasive, continuous, measurements of cardiac output (CO) and thoracic impedance (Zo) from which thoracic fluid content (TFC) can be derived assuming TFC=1000/Zo. This study was designed to evaluate the changes in TFC in comparison with the traditional indices of fluid removal (FR) and to understand the trends in CO changes in HD patients. Minute-by-minute changes in TFC and CO were prospectively collected using the bioreactance system (NICOM) in HD patients of a single unit. Changes in body weight (DeltaW), hematocrit (DeltaHct), and amount of FR were also measured. Twenty-five patients (age 77 +/- 11 years) were included. The TFC decreased in all patients by an average of 5.4 +/- 7.9 kohm(-1), weight decreased by 1.48 +/- 0.98 kg, and FR averaged 2.07 +/- 1.93 L over a 3- to 4-hour HD session. There were good correlations between DeltaTFC and DeltaW (R=0.80, P<0.0001) and FR (R=0.85, P<0.0001). DeltaHct (4.13 +/- 3.42%) was poorly correlated with DeltaTFC (R=0.35, P=0.12) and FR (R=0.40, P=0.07). The regression line between FR and TFC yielded FR=1.0024-0.1985TFC; thus, a 1 kohm(-1) change of Zo correlates with an approximately 200 mL change in total body water. The change in CO (-0.52 +/- 0.49 L/min m(2)) during HD did not correlate with FR (R=0.15, P=NS). Changes in TFC represented the monitored variable most closely related to FR. CO remained fairly constant in this stable patient cohort. Further studies in high-risk patients are warranted to understand whether TFC and CO monitoring can improve HD session management.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.314
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations43
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicHemodynamic Monitoring and TherapyFrench-language works237,207