MétaCan
Menu
Back to cohort
Record W1971521741 · doi:10.1021/ja808400s

Redox Actuation of a Microcantilever Driven by a Self-Assembled Ferrocenylundecanethiolate Monolayer: An Investigation of the Origin of the Micromechanical Motion and Surface Stress

2009· article· en· W1971521741 on OpenAlexaff
Lana Norman, Antonella Badia

Bibliographic record

VenueJournal of the American Chemical Society · 2009
Typearticle
Languageen
FieldPhysics and Astronomy
TopicMechanical and Optical Resonators
Canadian institutionsUniversité de MontréalRegroupement Québécois sur les Matériaux de Pointe
Fundersnot available
KeywordsChemistryMonolayerRedoxNanotechnologySurface stressMotion (physics)Surface (topology)Stress (linguistics)Chemical physicsClassical mechanicsPhysical chemistryInorganic chemistrySurface energyBiochemistry

Abstract

fetched live from OpenAlex

The electrochemically induced motion of free-standing microcantilevers is attracting interest as micro/nanoactuators and robotic devices. The development and implementation of these cantilever-based actuating technologies requires a molecular-level understanding of the origin of the surface stress that causes the cantilever to bend. Here, we report a detailed study of the electroactuation dynamics of gold-coated microcantilevers modified with a model, redox-active ferrocenylundecanethiolate self-assembled monolayer (FcC(11)SAu SAM). The microcantilever transducer enabled the observation of the redox transformation of the surface-confined ferrocene. Oxidation of the FcC(11)SAu SAM in perchlorate electrolyte generated a compressive surface stress change of -0.20 +/- 0.04 N m(-1), and cantilever deflections ranging from approximately 0.8 microm to approximately 60 nm for spring constants between approximately 0.01 and approximately 0.8 N m(-1). A comparison of the charge-normalized surface stress of the FcC(11)SAu cantilever with values published for the electrochemical oxidation of polyaniline- and polypyrrole-coated cantilevers reveals a striking 10- to 100-fold greater stress for the monomolecular FcC(11)SAu system compared to the conducting polymer multilayers used for electroactuation. The larger stress change observed for the FcC(11)SAu microcantilever is attributable to steric constraints in the close-packed FcC(11)SAu SAM and an efficient coupling between the chemisorbed FcC(11)S- monolayer and the Au-coated microcantilever transducer (vs physisorbed conducting polymers). The microcantilever deflection vs quantity of electrogenerated ferrocenium obtained in cyclic voltammetry and potential step/hold experiments, as well as the surface stress changes obtained for mixed FcC(11)S-/C(11)SAu SAMs containing different populations of clustered vs isolated ferrocenes, have permitted us to establish the molecular basis of stress generation. Our results strongly suggest that the redox-induced deflection of a FcC(11)SAu microcantilever is caused by a monolayer volume expansion resulting from collective reorientational motions induced by the complexation of perchlorate ions to the surface-immobilized ferroceniums. The cantilever responds to the lateral pressure exerted by an ensemble of reorienting ferrocenium-bearing alkylthiolates upon each other rather than individual anion pairing events. This finding has general implications for using SAM-modified microcantilevers as (bio)sensors because it indicates that the cantilever responds to collective in-plane molecular interactions rather than reporting individual (bio)chemical events.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.269

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.240
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations54
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueJournal of the American Chemical SocietySame topicMechanical and Optical ResonatorsFrench-language works237,207