Flow cytometric evaluation of material-induced platelet and complement activation
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
Flow cytometry is used to characterize the activation state of platelets and leukocytes within whole blood after contact for 4 h at 37 degrees C with various materials under conditions of low shear. The contact involved adding heparinized whole blood to small diameter tubes that were connected to two arms extending from a rocking platform. For all surfaces (polyethylene, polypropylene, Silastic, PVA hydrogel) tested there was strong evidence of platelet activation in the bulk blood: platelet-derived microparticles. P-selectin expression and platelet-leukocyte aggregates. Only contact with PVA hydrogel surfaces led to dramatic increases in CD11b up-regulation on monocytes and neutrophils that was inhibited by complement inhibition (sCRI). Flow cytometry was also used to evaluate the effectiveness of various agents to inhibit material-induced complement activation. The assay involved incubating 10 microm polystyrene beads for 1 h with serum at 37 degrees C before isolating the beads so as to label them with a monoclonal antibody against a neoantigen on SC5b-9. The beads were then identified by flow cytometry and the fluorescence associated with their SC5b-9 level recorded. The ability of C1-INH, pentamidine and benzamidine to moderately inhibit SC5b-9 levels suggests a role for classical complement activation in material-induced complement activation.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it