MétaCan
Menu
Back to cohort
Record W1971879213 · doi:10.3992/1943-4618-9.4.147

POWER CONSUMPTION COMPARISON OF FIVE BUILDING ENVELOPES IN THE NORTHERN PRAIRIE CLIMATE OF MANITOBA

2014· article· en· W1971879213 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueJournal of Green Building · 2014
Typearticle
Languageen
FieldEngineering
TopicHygrothermal properties of building materials
Canadian institutionsUniversity of Manitoba
Fundersnot available
KeywordsBuilding envelopeEnvironmental scienceThermal insulationRoofEnergy consumptionExpanded polystyreneEngineeringCivil engineeringThermalComposite materialMaterials scienceMeteorologyGeography

Abstract

fetched live from OpenAlex

ABSTRACT The energy efficiency of a building depends on building envelope performance. The results presented in this paper are the first of a long-term building envelope research project at the Alternative Village at the University of Manitoba in Winnipeg, Manitoba, Canada. Five test buildings were constructed using the following systems: two wood frames with fiberglass batt insulation and dense pack cellulose, one polyurethane structural insulated panels (PUR SIP), and two with the Stay in place PVC concrete form building system using 102mm and 204mm of concrete externally insulated with 102mm of expanded polystyrene foam. All of the buildings had a common foundation and roof system with a footprint of 23.8 m 2 . Blower door tests were conducted to determine air tightness. Each structure was heated with an electrical resistance heater and maintained at a constant internal temperature. The thermal gradient through the wall and power consumption were monitored. The study period discussed in this report represents the main heating season from October 2011 to April 2012 consisting of 209 days. Based on the power consumption, the PUR SIP consumed the least at 2498 kWh, while the 204 mm Stay in place PVC concrete form building used the most at 2898 kWh for the same time period. The thermal gradient through the cross section of the wood frame structures was compared through the cavity insulation and at the stud. It was found that the cellulose building provided better thermal resistance along the stud when compared to the fiberglass batt insulation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.097
Threshold uncertainty score0.560

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.261
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it