Percutaneous Transvenous Mitral Annuloplasty
Bibliographic record
Abstract
BACKGROUND: We assessed the safety and feasibility of permanent implantation of a novel coronary sinus mitral repair device (PTMA, Viacor Inc). METHODS AND RESULTS: Symptomatic (New York Heart Association class 2 or 3) patients with primarily functional mitral regurgitation (MR) were included. A diagnostic PTMA procedure was performed in the coronary sinus venous continuity. MR was assessed and the PTMA device adjusted to optimize efficacy. If MR reduction (> or =1 grade) was observed, placement of a PTMA implant was attempted. Implanted patients were evaluated with echocardiographic, quality of life, and exercise capacity metrics. Nineteen patients received a diagnostic PTMA study. Diagnostic PTMA was effective in 13 patients (MR grade 3.2+/-0.6 reduced to 2.0+/-1.0), and PTMA implants were placed in 9 patients. Four devices were removed uneventfully (7, 84, 197, and 216 days), 3 for annuloplasty surgery due to observed PTMA device migration and/or diminished efficacy. No procedure or device-related major adverse events with permanent sequela were observed in any of the diagnostic or implant patients. Sustained reductions of mitral annulus septal-lateral dimension from 3D echo reconstruction dimensions were observed (4.0+/-1.2 mm at 3 months). CONCLUSIONS: Percutaneous implantation of the PTMA device is feasible and safe. Acute results demonstrate a possibly meaningful reduction of MR in responding patients. Sustained favorable geometric modification of the mitral annulus has been observed, though reduction of MR has been limited. The PTMA method warrants continued evaluation and development.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".