MétaCan
Menu
Back to cohort
Record W1975668933 · doi:10.1097/imi.0000000000000014

Initial Experience with Intraventricular Repair Using CorMatrix Extracellular Matrix

2013· article· en· W1975668933 on OpenAlexaff
Bobby Yanagawa, Vivek Rao, Terrence M. Yau, Robert J. Cusimano

Bibliographic record

VenueInnovations Technology and Techniques in Cardiothoracic and Vascular Surgery · 2013
Typearticle
Languageen
FieldMedicine
TopicTissue Engineering and Regenerative Medicine
Canadian institutionsUniversity Health Network
Fundersnot available
KeywordsDecellularizationMedicineAneurysmCalcificationMyocardial infarctionExtracellular matrixCardiologyLeft Ventricular AneurysmSurgeryEndovascular aneurysm repairVentricleInternal medicineHeart failureAbdominal aortic aneurysmTissue engineeringBiomedical engineering

Abstract

fetched live from OpenAlex

OBJECTIVE: Pericardial patches for intraventricular repair are limited by progressive calcification, thickening, and retraction. The aim of this study was to evaluate the safety of CorMatrix extracellular matrix (ECM) for intraventricular repair of mechanical complications of myocardial infarction (MI). METHODS: CorMatrix ECM is a novel material synthesized from decellularized porcine small intestinal submucosa. Between July 2011 and October 2012, a total of 11 consecutive patients with post-MI complications including ventricular aneurysm (n = 7), ventricular septal defect (VSD; n = 3), and both aneurysm and VSD (n = 1) underwent patch repair using CorMatrix ECM. Clinical follow-up and interval transthoracic echocardiography data were collected. RESULTS: Eleven patients underwent Dor or linear left ventricular aneurysm repair and/or patch VSD repair. There were two reoperations and one surgical mortality but no cases of CorMatrix ECM repair failures. The mean ± SD clinical follow-up was 207 ± 211 days, and the longest follow-up was 642 days, during which there was no readmission for any cardiac cause or death. The mean ± SD transthoracic echocardiography follow-up was 176 ± 220 days, which demonstrated integrity of CorMatrix ECM repair in all cases. CONCLUSIONS: In our series, CorMatrix ECM was a safe alternative for ventricular patch repair of mechanical complications after MI in the short-term. This series supports the continued study of the efficacy and the regenerative potential of this novel material for cardiac repair.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.537
Threshold uncertainty score0.652

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.305
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations48
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueInnovations Technology and Techniques in Cardiothoracic and Vascular SurgerySame topicTissue Engineering and Regenerative MedicineFrench-language works237,207