Quantitative determination of parathyroid hypertensive factor by enzyme-linked immunosorbent assay

2000· article· en· W1976019654 on OpenAlexaff
Svetlana M. Krylova, P.K.T. Pang, Jing Shan, R LEWANCZUK, Christina G. Benishin

Bibliographic record

VenueAmerican Journal of Hypertension · 2000
Typearticle
Languageen
FieldMedicine
TopicErythrocyte Function and Pathophysiology
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsImmunoassayHorseradish peroxidaseMedicineAntibodyHaptenCoefficient of variationMolecular biologyReference rangeEnzymeConjugateMicrotiter plateAntigenEndocrinologyInternal medicineChemistryChromatographyImmunologyBiochemistryBiology

Abstract

fetched live from OpenAlex

A new competitive enzyme immunoassay for the detection parathyroid hypertensive factor (PHF) in human plasma using a PHF-horseradish peroxidase conjugate and IgM antibody adsorbed on the microtiter plate was established. The antibodies raised against rat PHF could recognize human PHF. Cross-reactivity of anti-PHF antibodies with other serum haptens and proteins was negligible. Conjugation of PHF with horseradish peroxidase did not neutralize the antigen activity. The limit of detection of PHF was 0.02 U/mL in reference units and PHF levels between 0.02 and 1 U/mL could be detected. Within-run coefficient of variation (CV) was less than 10%, and between-run CV was less than 15% for over the dynamic range of the assay. Preliminary clinical studies were performed with plasma samples from hypertensive patients with confirmed diagnosis. Parathyroid hypertensive factor levels, as detected with this immunoassay, were positively correlated with PHF levels detected with the semiquantitative blood pressure (BP) bioassay previously used. Parathyroid hypertensive factor levels detected with the enzyme-linked immunosorbent assay (ELISA) were also correlated with BP in patients. The PHF ELISA provides a selective, simple, and rapid method that can be used for routine determination of PHF in human plasma, and provides useful clinical information.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.409
Threshold uncertainty score0.526

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.275
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of HypertensionSame topicErythrocyte Function and PathophysiologyFrench-language works237,207