MétaCan
Menu
Back to cohort
Record W1976406014 · doi:10.1097/hco.0b013e328341384e

Cardiovascular implantable electrophysiological device-related infections: a review

2010· review· en· W1976406014 on OpenAlexaff
Paul A. Gould, Lorne J. Gula, Raymond Yee, Allan C. Skanes, George J. Klein, Andrew D. Krahn

Bibliographic record

VenueCurrent Opinion in Cardiology · 2010
Typereview
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsLondon Health Sciences CentreWestern University
Fundersnot available
KeywordsMedicineIntensive care medicinePercutaneousConcomitantAntibioticsImplantable cardioverter-defibrillatorSurgeryInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE OF REVIEW: The use of cardiac implantable electrophysiological device (CIED) therapy in the management of cardiac disease is increasing with the improvements in technology of permanent pacemaker and implantable cardioverter defibrillators. Accordingly CIED-related infections are increasing and have become an important clinical problem. The purpose of this review is to summarize current literature on the epidemiology, risk factors, pathophysiology, diagnosis and management of CIED-related infections. RECENT FINDINGS: The diagnosis and management of CIED-related infections can be difficult. Recent research would suggest extraction of all CIED components, and concomitant appropriate antibiotic therapy is the principal management modality of CIED component and pocket infection. The exact duration of antibiotic therapy and timing of re-implantation still require further delineation in the absence of comparative evidence; however, improvements in technologies such as the excimer laser have enabled percutaneous extraction to be performed effectively and safely in the vast majority of patients. Differentiating CIED-related infection from noninfected mechanical issues that may not require extraction or antibiotics can be very difficult. Research is continuing into better methods to diagnose and treat infection. SUMMARY: CIED-related infections are an important clinical problem with ongoing research to improve diagnosis and treatment. Currently, percutaneous CIED extraction and antibiotic therapy are the mainstay of treatment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.901
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0080.005
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.112
GPT teacher head0.421
Teacher spread0.309 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2010
Admission routes1
Has abstractyes

Explore more