fetched live from OpenAlex

Purpose: We assess the impact of the uncertainty of glandular/adipose tissue proportion on dose distribution inside the breast for LDR brachytherapy. Furthermore, we propose a semiautomatic tissue segmentation method to be used in Monte Carlo (MC) calculations for breast LDR patients. Methods & materials: Post‐implant CT exams of five breast brachytherapy patients are imported into our Geant4 MC platform. The CTV and the PTV were contoured by the oncologist; the external contours of the breast, skin, lungs and the ribs were made manually by a physicist. In a first step, the breast is assigned with different proportions of glandular/adipose tissue (ρ = 100/0, 75/25, 50/50, 25/75, 0/100) in order to study the impact of this variation on clinical dosimetries. In a second step, a density‐based semiautomatic segmentation of breast tissue is used to identify glandular from adipose regions inside the breast and to create a more representative breast anatomy with appropriate chemical compositions. A TG43‐like simulation (SMC: Superposition MC) is also performed for each patient. Does‐Volume‐Histograms are used to visualize the effect of dose reduction. Results: In all patients, the glandular/adipose proportion, affects the dose distribution across the breast. The higher the adipose proportion in the breast tissue, the larger is the dose reduction across the organ. The D90 clinical parameter is reduced by up to 22% when the breast is entirely made of adipose. The semiautomatic contouring enabled a patient‐dependent segmentation of the glandular and adipose regions leading to more accurate dose calculations for each patient. Conclusion: Using realistic chemical compositions in MC simulations is achievable for MC calculations. Unlike external‐beam radiotherapy, the low‐energy emission of 103Pd is strongly affected by the heterogeneities adipose proportion in breast. A patient‐dependant glandular/adipose segmentation in breast is important for accurate dose determinations in MC, especially for breast LDR brachytherapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.003
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.373
Teacher spread0.345 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicMedical Imaging Techniques and Applications→French-language works237,207→