MétaCan
Menu
Back to cohort
Record W1977940077 · doi:10.1097/icu.0b013e32834ff1e7

Micro-invasive glaucoma surgery

2012· review· en· W1977940077 on OpenAlexaff
Hady Saheb, Iqbal Ike K. Ahmed

Bibliographic record

VenueCurrent Opinion in Ophthalmology · 2012
Typereview
Languageen
FieldMedicine
TopicGlaucoma and retinal disorders
Canadian institutionsCredit Valley HospitalMcGill University Health CentreUniversity of TorontoHEC MontréalMcGill University
Fundersnot available
KeywordsMedicinePhacoemulsificationGlaucomaTrabeculectomyGlaucoma surgeryIntraocular pressureOphthalmologyGonioscopyCataract surgeryVisual acuity

Abstract

fetched live from OpenAlex

PURPOSE OF REVIEW: There is an increasing interest and availability of micro-invasive glaucoma surgery (MIGS) procedures. It is important that this increase is supported by sound, peer-reviewed evidence. This article will define MIGS, review relevant publications in the period of annual review and discuss future directions. RECENT FINDINGS: The results of the pivotal trial comparing a trabecular micro-bypass stent (iStent, Glaukos Corporation, Laguna Hills, CA, USA) combined with phacoemulsification to phacoemulsification alone showed a significantly higher percentage of patients with unmedicated intraocular pressure (IOP) ≤ 21 mmHg, and a comparable safety profile. Initial results are published regarding a second-generation micro-bypass stent (iStent inject, Glaukos Corporation, Laguna Hills, CA, USA), a canalicular scaffold (Hydrus, Ivantis Inc., Irvine, CA, USA) and an ab interno suprachoroidal microstent (CyPass, Transcend Medical, Menlo Park, CA, USA), showing a decrease in mean postoperative IOP. Phaco-Trabectome (Ab interno trabeculectomy Trabectome, NeoMedix Inc., Tustin, CA, USA) was compared to phacotrabeculectomy and showed less IOP reduction, less postoperative complications, and a similar success rate. Similar success rates were found with the comparison of excimer laser trabeculostomy (ELT, AIDA, Glautec AG, Nurnberg, Germany) and selective laser trabeculoplasty. A number of publications review the importance of the location of implantable devices, intraoperative gonioscopy, cost-effectiveness and quality-of-life studies, and randomized clinical trials. SUMMARY: MIGS procedures offer reduction in IOP, decrease in dependence on glaucoma medications and an excellent safety profile. Their role within our glaucoma treatment algorithm continues to be clarified and differs from the role of more invasive glaucoma surgeries such as trabeculectomy or glaucoma drainage devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.014
Threshold uncertainty score0.048

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0030.002
Bibliometrics0.0040.003
Science and technology studies0.0000.001
Scholarly communication0.0020.002
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0140.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.170
GPT teacher head0.413
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations625
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueCurrent Opinion in OphthalmologySame topicGlaucoma and retinal disordersFrench-language works237,207