MétaCan
Menu
Back to cohort

A Rewarming Maneuver Demonstrates the Contribution of Blood Flow to Electrode Cooling During Internally Irrigated RF Ablation

2007· article· en· W1978935466 on OpenAlexaff
Joshua M. Cooper, John L. Sapp, David Robinson, Laurence M. Epstein, William G. Stevenson

Bibliographic record

VenueJournal of Cardiovascular Electrophysiology · 2007
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrhythmias and Treatments
Canadian institutionsQueen Elizabeth II Health Sciences CentreDalhousie University
Fundersnot available
KeywordsMedicineAblationElectrodeRf ablationBlood flowIntracardiac injectionCatheter ablationBiomedical engineeringCatheterNuclear medicineCardiologySurgeryChemistry

Abstract

fetched live from OpenAlex

INTRODUCTION: Titration of radiofrequency (RF) ablation energy to avoid steam pops while maximizing lesion size is difficult because of disparities between electrode and tissue temperature. We hypothesized that the variable contribution of local blood flow to electrode cooling contributes to electrode-tissue temperature disparity, even with an irrigated RF catheter. METHODS AND RESULTS: Forty RF lesions were made in the atria of live swine with an internally irrigated cooled RF catheter. Prior to RF delivery, the catheter tip was cooled and then allowed to rewarm to body temperature by stopping irrigant flow. The rewarming time (RT) was noted. The catheter was again cooled and RF energy delivered, with power titrated to achieve electrode temperature of 40 degrees C, which was previously defined as the approximate upper limit of safety. Lesion formation and steam pops were observed with intracardiac echocardiography. The RT ranged from 10 to 47 seconds. Nine steam pops were seen. The mean RT for lesions with pops was faster than those without (20 vs. 33 seconds, P = 0.003). The 20 lesions with faster RT required more power to achieve target temperature than the 20 lesions with slower RT (P = 0.01). Eight of nine steam pops occurred in the group with faster RT. CONCLUSIONS: RT quantifies convective heating by blood prior to RF. Faster RT predicts greater cooling by blood during irrigated RF, a greater power requirement to reach target electrode temperature, and a higher risk of steam pops during fixed-temperature ablation. RT therefore can demonstrate the variation in blood cooling with each lesion and can be used to tailor energy delivery to maximize efficacy and safety.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.232
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ElectrophysiologySame topicCardiac Arrhythmias and TreatmentsFrench-language works237,207