MétaCan
Menu
Back to cohort
Record W1980542956 · doi:10.1177/0309364611426905

The influence of passive wrist joints on the functionality of prosthetic hands

2011· article· en· W1980542956 on OpenAlexafffund
Peter Kyberd

Bibliographic record

VenueProsthetics and Orthotics International · 2011
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsUniversity of New Brunswick
FundersCanadian Institutes of Health Research
KeywordsWristUlnar deviationPhysical medicine and rehabilitationMedicineProsthesisComputer sciencePhysical therapyOrthodonticsSurgery

Abstract

fetched live from OpenAlex

Background: The addition of a passive wrist to a single degree of freedom prosthesis has an effect on its functionality. The amount of impact is undetermined. Objectives: To measure the grasping function of a commercial single degree of freedom hands with and without two forms of passive wrist flexor. Study Design: Form-board and timed tasks. Method: Repeated measures with a single subject using a validated assessment tool. The test measured the function of one conventional, single axis, powered hand controlled by the same myocontroller format. It was used in conjunction with a passive three position wrist flexor, a wrist with compliance in the flex/extend and radial/ulnar deviation and compared with a hand without these axes. Results: The overall functional score of the hand alone was 80 out of 100. The use of a wrist flexion unit resulted in a higher score (83) and the compliant wrist achieved a score of 79. The addition of a wrist allowed improved performance in Power, Lateral and Tips grips for both wrist designs, in addition the Extension grip was improved with the compliant wrist. Conclusion: Wrist flexion had a positive impact on the functional score. It enabled some tasks to be performed quicker and with less difficulty. Clinical relevance The majority of prosthetic hands have pro/supination yet there is little evidence about what impact this, or any other motion at the wrist, has on the overall functional capabilities of a prosthetic hand (i.e. grip). A commercial myoelectric prosthetic hand when used with and without two different wrist designs can potentially improve grip performance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.007
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.210
Teacher spread0.193 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueProsthetics and Orthotics InternationalSame topicMuscle activation and electromyography studiesFrench-language works237,207