MétaCan
Menu
Back to cohort
Record W1980751238 · doi:10.2134/jeq2003.3680

Enumeration of Waterborne <i>Escherichia coli</i> with Petrifilm Plates

2003· article· en· W1980751238 on OpenAlexaboutno aff
J. H. Vail, Ruth Morgan, C. R. Merino, Felicitas S. Gonzales, R. Miller, Jeffrey L. Ram

Bibliographic record

VenueJournal of Environmental Quality · 2003
Typearticle
Languageen
FieldEnvironmental Science
TopicFecal contamination and water quality
Canadian institutionsnot available
FundersNational Institute of General Medical SciencesNational Metal and Materials Technology CenterGrand Valley State UniversityNational Institutes of HealthWayne State UniversityNational Science Foundation
KeywordsEscherichia coliMacConkey agarEnumerationFecal coliformPolymerase chain reactionChemistryFood scienceMicrobiologyVeterinary medicineWater qualityBiologyMathematicsEcologyMedicineBiochemistry

Abstract

fetched live from OpenAlex

Escherichia coli is often monitored in environmental waters as an indicator of the possible presence of human pathogens associated with feces. Petrifilm E. coli/coliform count plates (3M, Minneapolis, MN), previously validated for enumerating E. coli in food, were tested for monitoring E. coli in environmental water. Escherichia coli counts in environmental water samples enumerated with Petrifilm were significantly correlated (R > 0.9; slope = 0.9-1.0; p < 0.001) with counts obtained with three commonly used methods, mTEC (Becton Dickinson, Sparks, MD), m-ColiBlue (Hach, Loveland, CO), and Colilert-18/IDEXX Quanti-Tray 2000 (IDEXX, Westbrook, ME). Blue colonies on Petrifilm plates were most reliably identified as E. coli when accompanied by gas formation, as determined by characterization of the colonies on MacConkey agar plates (PML Microbiologicals, Mississauga, ON, Canada) and by polymerase chair reaction (PCR) with E. coli-specific primers. The main disadvantage of Petrifilm plates for environmental water testing is the small volume (1 mL per sample) that can be tested; however, the plates appear to be suitable for screening and locating sites that exceed criteria for total body and partial body contact. Simplicity of use and storage, reliability, and relatively low cost make Petrifilm plates suitable for volunteer-based and educational water quality monitoring applications, particularly when used as a preliminary screening method to identify problem sites.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.342
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.230
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations56
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Environmental QualitySame topicFecal contamination and water qualityFrench-language works237,207