MétaCan
Menu
Back to cohort
Record W1982729133 · doi:10.1097/brs.0b013e318145a91c

A Quantitative and Reproducible Method to Assess Cord Compression and Canal Stenosis After Cervical Spine Trauma

2007· article· en· W1982729133 on OpenAlexaff
Julio C. Furlan, Michael G. Fehlings, Eric M. Massicotte, Bizhan Aarabi, Alexander R. Vaccaro, Christopher M. Bono, Ignacio Madrazo, Carlos Villanueva, Jonathan N. Grauer, David J. Mikulis

Bibliographic record

VenueSpine · 2007
Typearticle
Languageen
FieldMedicine
TopicCervical and Thoracic Myelopathy
Canadian institutionsToronto Western HospitalUniversity Health NetworkUniversity of Toronto
Fundersnot available
KeywordsMedicineIntraclass correlationInter-rater reliabilityIntra-rater reliabilityInterclass correlationRadiologyNuclear medicineMagnetic resonance imagingSpinal stenosisReliability (semiconductor)Confidence intervalRating scaleLumbarMathematicsStatistics

Abstract

fetched live from OpenAlex

STUDY DESIGN: Reliability study. OBJECTIVE: To assess the intrarater and interrater reliability of a recently described technique to measure of maximum canal compromise (MCC) and maximum spinal cord compression (MSCC) using digitized and magnified images in the setting of traumatic cervical spinal cord injury (SCI). SUMMARY OF BACKGROUND DATA: The extent of MCC and MSCC is of clinical and prognostic value in the setting of traumatic cervical SCI. However, concerns remain regarding the accuracy of measurements based on hard copy images. We hypothesized that the interrater and intrarater reliability of these assessments would be enhanced using magnified digitized images and software-based measurement tools. METHODS: Midsagittal MRI and CT images of cervical spine were selected from 5 individuals with acute traumatic cervical SCI. Measurements of MCC using CT scan and T1-weighted MRI and measurements of MSCC based on T2-weighted MR images were independently estimated by 13 raters on 10 occasions. RESULTS: The intrarater reliability for CT-MCC, T1-weighted MRI-MCC and T2-weighted MRI-MSCC was high in the 10 rounds in each patient. In addition, the mean intrarater interclass correlation coefficient was 0.72 +/- 0.05 for the CT-MCC, 0.70 +/- 0.07 for the T1-weighted MRI-MCC, and 0.68 +/- 0.11 for the T2-weighted MRI-MSCC. The mean interrater interclass correlation coefficients were 0.43 +/- 0.02 for the CT-MCC, 0.61 +/- 0.03 for the T1-weighted MRI-MCC, and 0.55 +/- 0.05 for the evaluation of T2-weighted MRI-MSCC. CONCLUSION: Our study has demonstrated that the intrarater reliability for the instrument to assess MCC and MSCC in the setting of traumatic SCI was high. The interrater ICCs at a moderate level of reliability combined with our results using analysis of variance with post hoc tests indicate that the measurements of MCC and MSCC are reproducible, which supports the use of these radiologic parameters in the clinical and research settings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.922
Threshold uncertainty score0.534

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.068
GPT teacher head0.401
Teacher spread0.333 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations55
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicCervical and Thoracic MyelopathyFrench-language works237,207