MétaCan
Menu
Back to cohort
Record W1983233366 · doi:10.1118/1.2868760

Improvement of the spatial resolution of the MicroPET R4 scanner by wobbling the bed

2008· article· en· W1983233366 on OpenAlexafffund
Joon Young Suk, Christopher J. Thompson, А. А. Лабуда, Andrew L. Goertzen

Bibliographic record

VenueMedical Physics · 2008
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of ManitobaMontreal Neurological Institute and HospitalMcGill UniversityUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsSpeed wobbleImage resolutionScannerImaging phantomComputer visionComputer scienceArtificial intelligenceNuclear medicinePhysicsOpticsMedicine

Abstract

fetched live from OpenAlex

The MicroPET R4 scanner was designed for imaging small rodents such as mice and rats. In many cases the spatial resolution of this system is not sufficient for resolving structures of interest. In order to improve the spatial resolution of the MicroPET R4 through improved spatial sampling, the authors have implemented a variable radius eccentric motion, commonly referred to as wobbling, which is applied to the animal bed during scanning. The wobble motion is incorporated into the sinograms using modified histogramming software, capable of reading the bed wobble position from the list-mode data. The histogramming software corrects the data for the dwell time, apparent crystal location, and crystal-pair efficiency and applies a resolution matching filter. The data acquisition, reconstruction, and image display programs provided from the manufacturer required no modifications. For all studies a wobble period of 8 s was used. The optimal wobble radius was found to be 1.50 mm. The wobbled bed acquisition technique was tested by scanning a resolution phantom and a rat. Images from both studies acquired when using the wobble motion showed an improved spatial resolution when compared with comparable images acquired without the wobble motion. The bed wobbling mechanism can be added to any MicroPET system without major changes and without compromising any imaging modes. Implementing the wobble mechanism may represent a cost-effective method to upgrade the spatial resolution of a MicroPET when compared to the purchase of a newer generation system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.532
Threshold uncertainty score0.314

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.276
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2008
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207