MétaCan
Menu
Back to cohort
Record W1984416442 · doi:10.1118/1.4735147

SU‐E‐T‐90: Investigation of Different Bleaching Wavelengths on the Absorbed‐Dose Sensitivity of NanoDot OSLDs Exposed to 6 MV X‐Ray Beams

2012· article· en· W1984416442 on OpenAlexaffabout
Azeez Omotayo, Joanna Cygler, Gabriel O. Sawakuchi

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldMaterials Science
TopicLuminescence Properties of Advanced Materials
Canadian institutionsCarleton UniversityOttawa Hospital
Fundersnot available
KeywordsNanodotMaterials scienceIrradiationOptically stimulated luminescenceWavelengthOpticsOptoelectronicsPhosphorLuminescencePhysics

Abstract

fetched live from OpenAlex

PURPOSE: :C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. METHODS: OSLDs of the nanoDot type were used and readout with a microStar InLight reader. To determine the effect of different bleaching wavelengths on the luminescence response of nanoDot OSLDs, we optically reset (bleached) the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120 and 600 min; and (ii) with a long pass filter for 55, 600 and 2400 min. The long pass filter blocks wavelengths below 495 nm, hence the longer bleaching duration to attain equivalent OSL signals as bleaching directly under the lamps. Changes in the sensitivity of the nanoDot OSLDs were determined for an irradiation-readout-bleaching-readout cycle, after irradiations with 1 and 10 Gy dose fractions. RESULTS: The nanoDot OSLDs presented a linear response to dose up to 2 Gy and supra-linear response afterwards. They produced different OSL signal loss and fading behaviors for doses of 1 and 10 Gy. OSLDs bleached for 120 min and 600 min without and with the filter in 1 Gy fractions, did not exhibit any significant change in sensitivity over an accumulated dose of 7 Gy. The OSLDs exposed with 10 Gy fractions exhibited a small under-response when bleached with filter, and an over-response when bleached directly without filter. CONCLUSIONS: The nanoDot OSLDs may be reused without a significant sensitivity change for accumulated doses below 7 Gy. However, for accumulated doses beyond 10 Gy, nanoDot OSLDs show significant sensitivity change and hence, need to be recalibrated for reuse. We also concluded that the light spectrum used to reset the OSLDs has an influence on the sensitivity of the detectors. Natural Sciences and Engineering Research Council of Canada.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.528

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.257
Teacher spread0.226 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicLuminescence Properties of Advanced MaterialsFrench-language works237,207