MétaCan
Menu
← Back to cohort
Record W1984629459 · doi:10.1118/1.4814523

SU-E-T-88: Evaluation of the Dose-Rate Dependency of GAFCHROMIC EBT3

2013· article· en· W1984629459 on OpenAlexaff
Gregory J. Twork, Arman Sarfehnia

Bibliographic record

VenueMedical Physics · 2013
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcGill University Health Centre
Fundersnot available
KeywordsDosimetryMaterials scienceIonization chamberDose rateImaging phantomIrradiationPercentage depth dose curveNuclear medicineOpticsPhysicsIonMedicineNuclear physicsMedical physics

Abstract

fetched live from OpenAlex

Purpose: To evaluate the effect of different dose rates on the optical density (OD) for the commercially available GAFCHROMIC EBT3 film using a Novalis TX. Methods: 3×3 cm2 pieces of GAFCHROMIC EBT3 (A12141101) were placed on the surface of a 20×20×20 cm3 solid water phantom. A 2 cm thick block of solid water was placed on the film for build up. The machine output was monitored using a Farmer-type chamber located at a depth of 10 cm below the films. Chamber ion recombination as a function of dose rate was accounted for, and pressure and temperature were monitored throughout. The monitor unites were calculated such that a certain dose (50, 100, 500 cGy) was delivered at the level of the film. The dose rate was varied between 50 and 1000 cGy/min through changing both machine settings (100–600 MU/min, 1000 MU/min in SRS mode and source-to-surface distance SSD (75–135 cm). The films were scanned 24 hours post irradiation, and the resulting changes in net OD were compared against the corresponding dose rate. Results: Preliminary examination of net OD results shows a small dependence on dose rate, but within the uncertainty of the measurements. As such, within the uncertainties of clinical film dosimetry, the GAFCHROMIC EBT3 films are independent of dose rate (50–1000 cGy/min) irrespective of the total delivered dose (between 50–500 cGy). Conclusion: Results suggest GAFCHROMIC EBT3 films to be dose rate independent to within 3% for a wide range of dose rates (and total delivered doses) that are normally used in clinical settings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.307
Teacher spread0.290 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→