MétaCan
Menu
Back to cohort
Record W1985766638 · doi:10.1117/12.2005512

Broadly tunable high-energy spectrally focused CARS microscopy with chemical specificity and high resolution for biological samples

2013· article· en· W1985766638 on OpenAlexaff
Craig Brideau, Kelvin W. C. Poon, Peter K. Stys

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2013
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicSpectroscopy Techniques in Biomedical and Chemical Research
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsFemtosecondOpticsSupercontinuumPicosecondMaterials scienceLaserRaman scatteringFiber laserRaman spectroscopyOptoelectronicsMicroscopyYtterbiumWavelengthPhysicsPhotonic-crystal fiber

Abstract

fetched live from OpenAlex

The current trend in laser sources for Coherent Anti-Stokes Raman Scattering (CARS) microscopy consists of picosecond optical parametric oscillators (OPO)s and femtosecond-pumped fiber supercontinuum sources. While both methods are proven CARS performers, restricted wavelength tuning range and low power limit the Raman lines and types of samples that may be practically interrogated. To address these limitations, we present a novel, highly tunable spectrally focused femtosecond Optical Parametric Amplifier (OPA) and microscope system optimized for CARS microscopy. The laser source consists of an amplified ytterbium fiber laser driving a pair of OPAs producing two outputs that produce tunable femtosecond pulses from 650 to 1300nm. Each OPA may be tuned independently of the other over its entire range, allowing the addressing of any arbitrary wavenumber from 0 to 7700 cm-1. Additionally, the complete freedom of tuning allows one beam to be set at the optimal wavelength for a complementary technique, such as twophoton fluorescence or second harmonic, while the second beam is then tuned to the desired wavenumber difference for CARS. The femtosecond pulses are chirped out to the picosecond regime, reducing non-resonant background and providing improved spectral resolution. Typically, OPA systems are limited to kHz repetition rates, making them impractical for imaging applications. In contrast, our OPA system is driven at 1 MHz, providing a sufficient pulse rate for high-resolution imaging at rates of 1-2 frames per second. The 1 MHz rate preserves good pulse energy while reducing average power, thus limiting sample photo damage.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.238
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicSpectroscopy Techniques in Biomedical and Chemical ResearchFrench-language works237,207