MétaCan
Menu
Back to cohort
Record W1985971010 · doi:10.2136/vzj2005.0116

Electrical Conductivity of a Failed Septic System Soil Absorption Field

2006· article· en· W1985971010 on OpenAlexaff
Brad D. Lee, Byron Jenkinson, James A. Doolittle, Richard S. Taylor, John W. Tuttle

Bibliographic record

VenueVadose Zone Journal · 2006
Typearticle
Languageen
FieldEarth and Planetary Sciences
TopicGeophysical and Geoelectrical Methods
Canadian institutionsDuPont (Canada)
FundersIndiana Water Resources Research Center, Purdue University
KeywordsTransectWater contentSoil waterSeptic tankMoistureEnvironmental scienceSoil scienceGeologyAbsorption (acoustics)Geotechnical engineeringMaterials scienceEnvironmental engineeringComposite material

Abstract

fetched live from OpenAlex

Locating existing septic systems and determining the extent of soil contamination after septic system failure can be destructive, time consuming, and a nuisance to homeowners. The objective of this study was to determine the effectiveness of noninvasive electromagnetic induction (EMI) for locating a failed septic system in fine‐textured glacial‐till‐derived soils. Components of a failed septic system were located with a push probe, georeferenced with a theodolite, and surveyed with a dual receiver EMI sensor (DUALEM‐2) in December 2001 (wet soil moisture condition) and July 2002 (dry soil moisture condition). Three transects located perpendicular to the soil absorption field trenches were sampled to a depth of 1.2 m and used to ground reference the EMI survey. Near‐surface (1‐m depth) apparent conductivity (EC a ) was significantly correlated to unweighted average electrical conductivity from soil saturated paste extracts (EC sat ; r = 0.79). The EC a below the soil absorption field was higher than the surrounding native soil under both dry and wet soil moisture conditions. Individual soil absorption trenches had a higher EC a than background EC a under both soil moisture conditions. A higher EC a pattern that was apparent in December 2001 associated with discharge of wastewater at shallow depths was not evident in July 2002 after the system had been abandoned for 6 mo. While more research is warranted, results from this study suggest that electromagnetic induction is a promising technique to identify the location of septic system components, failed septic systems, and their associated effluent plumes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.801
Threshold uncertainty score0.772

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.215
Teacher spread0.205 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueVadose Zone JournalSame topicGeophysical and Geoelectrical MethodsFrench-language works237,207