fetched live from OpenAlex

OBJECTIVES: To characterize the ability of high-intensity focused ultrasound to achieve thrombolysis in vitro and investigate the feasibility of this approach as a means of restoring blood flow in thrombus-occluded arteries in vivo. MATERIALS AND METHODS: All experiments were approved by the Institutional Animal Care Committee. Thrombolysis was performed with a 1.51-MHz focused ultrasound transducer with pulse lengths of 0.1 to 10 milliseconds and acoustic powers up to 300 W. In vitro experiments were performed with blood clots formed from rabbit arterial blood and situated in 2-mm diameter tubing. Both single location and flow bypass recanalization experiments were conducted. In vitro clot erosion was assessed with 30-MHz ultrasound, with debris size measured with filters and a Coulter counter. In vivo clots were initiated in the femoral arteries of rabbits (n = 26). Cavitation signals from bubbles formed during exposure were monitored. In vivo flow restoration was assessed with 23-MHz Doppler ultrasound. RESULTS: At a single location, in vitro clot erosion volumes increased with exposure power and pulse length, with debris size reducing with increasing pulse length. Flow bypass experiments achieved 99.2% clot erosion with 1.1% of debris above 0.5 mm in size. In vivo, 10 milliseconds pulses were associated with bleeding, but at 1 millisecond, it was feasible to achieve partial flow restoration in 6 of the 10 clots with only 1 of the 10 showing evidence of bleeding. In all cases, thrombolysis occurred only in the presence of cavitation. CONCLUSION: High-intensity focused ultrasound thrombolysis is feasible as a means of restoring partial blood flow in thrombus-occluded arteries in the absence of thrombolytic agents. The potential for bleeding with this approach requires further investigation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.219
Teacher spread0.204 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations124
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueInvestigative RadiologySame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207