MétaCan
Menu
Back to cohort
Record W1986361216 · doi:10.1097/rli.0b013e31823cc75c

In Vitro and In Vivo High-Intensity Focused Ultrasound Thrombolysis

2012· article· en· W1986361216 on OpenAlex
Cameron Wright, Kullervo Hynynen, David E. Goertz

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueInvestigative Radiology · 2012
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsSunnybrook Health Science CentreUniversity of TorontoHealth Sciences Centre
FundersNational Institute of Biomedical Imaging and Bioengineering
KeywordsThrombolysisBiomedical engineeringUltrasoundIn vivoBlood flowThrombusMedicineUltrasonic sensorMaterials scienceNuclear medicineRadiologySurgeryCardiologyMyocardial infarction

Abstract

fetched live from OpenAlex

OBJECTIVES: To characterize the ability of high-intensity focused ultrasound to achieve thrombolysis in vitro and investigate the feasibility of this approach as a means of restoring blood flow in thrombus-occluded arteries in vivo. MATERIALS AND METHODS: All experiments were approved by the Institutional Animal Care Committee. Thrombolysis was performed with a 1.51-MHz focused ultrasound transducer with pulse lengths of 0.1 to 10 milliseconds and acoustic powers up to 300 W. In vitro experiments were performed with blood clots formed from rabbit arterial blood and situated in 2-mm diameter tubing. Both single location and flow bypass recanalization experiments were conducted. In vitro clot erosion was assessed with 30-MHz ultrasound, with debris size measured with filters and a Coulter counter. In vivo clots were initiated in the femoral arteries of rabbits (n = 26). Cavitation signals from bubbles formed during exposure were monitored. In vivo flow restoration was assessed with 23-MHz Doppler ultrasound. RESULTS: At a single location, in vitro clot erosion volumes increased with exposure power and pulse length, with debris size reducing with increasing pulse length. Flow bypass experiments achieved 99.2% clot erosion with 1.1% of debris above 0.5 mm in size. In vivo, 10 milliseconds pulses were associated with bleeding, but at 1 millisecond, it was feasible to achieve partial flow restoration in 6 of the 10 clots with only 1 of the 10 showing evidence of bleeding. In all cases, thrombolysis occurred only in the presence of cavitation. CONCLUSION: High-intensity focused ultrasound thrombolysis is feasible as a means of restoring partial blood flow in thrombus-occluded arteries in the absence of thrombolytic agents. The potential for bleeding with this approach requires further investigation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.472
Threshold uncertainty score0.554

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.219
Teacher spread0.204 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it