MétaCan
Menu
Back to cohort

Bone Tissue Responses to Surface‐Modified Zirconia Implants: A Histomorphometric and Removal Torque Study in the Rabbit

2005· article· en· W1986587299 on OpenAlexvenueno aff
Lars Sennerby, Amir Dasmah, Birgitta Larsson, Mattias Iverhed

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2005
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsCubic zirconiaMaterials scienceTitaniumImplantSurface roughnessBiomedical engineeringOsseointegrationDentistryScanning electron microscopeTibiaZirconiumBiocompatibilityCeramicComposite materialMedicineSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Zirconia ceramics are biocompatible and have mechanical properties that make them suitable as materials for dental implants. Little is known about how surface modification influences the stability and bone tissue response to zirconia implants. PURPOSE: The objective of the investigation was to histologically and biomechanically evaluate the bone tissue response to zirconia implants with two different surface modifications in comparison with machined, nonmodified zirconia implants and oxidized titanium implants. MATERIALS AND METHODS: Threaded zirconia implants with a diameter of 3.75 mm with either a machined surface (Zr-Ctr) or one of two surface modifications (Zr-A and Zr-B) were manufactured. Oxidized titanium (Ti-Ox) implants 3.75 mm in diameter were also used. The implants were characterized with regard to surface topography using an interferometer. Twelve rabbits received 96 implants using a rotational scheme, two in each tibia and two in each femur. The implants in six rabbits were subjected to removal torque (RTQ) tests after a healing period of 6 weeks. The implants in the remaining six animals were removed en bloc for light microscopic analysis. Back-scatter scanning electron microscopic (BS-SEM) analyses were used to evaluate the state of the bone-implant interface at the modified zirconia implants after RTQ testing. RESULTS: The Ti-Ox and Zr-A implants showed the highest surface roughness, followed by the Zr-B implants and, finally, the Zr-Ctr implants. The nonmodified ZrO2 implants showed statistically significant lower RTQs than all other implants. No significant differences in bone-implant contact or bone area filling the threads were observed. BS-SEM showed intact surface layers of the surface-modified implants after RTQ testing and revealed fracture of the interface bone rather than a separation. CONCLUSION: The present study showed a strong bone tissue response to surface-modified zirconia implants after 6 weeks of healing in rabbit bone. The modified zirconia implants showed a resistance to torque forces similar to that of oxidized implants and a four- to fivefold increase compared with machined zirconia implants. The findings suggest that surface-modified zirconia implants can reach firm stability in bone.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.161
GPT teacher head0.486
Teacher spread0.325 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations318
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207