MétaCan
Menu
Back to cohort
Record W1987790126 · doi:10.1016/j.jcrs.2008.05.024

Fellow-eye comparison of posterior capsule opacification with AcrySof SN60AT and AF-1 YA-60BB blue-blocking intraocular lenses

2008· article· en· W1987790126 on OpenAlexaff
Joanne Hancox, David J. Spalton, Georgia Cleary, J.F. Boyce, Mayank A. Nanavaty, Sri Thyagarajan, John Marshall

Bibliographic record

VenueJournal of Cataract & Refractive Surgery · 2008
Typearticle
Languageen
FieldMedicine
TopicIntraocular Surgery and Lenses
Canadian institutionsSt. Thomas Hospital
Fundersnot available
KeywordsIntraocular lensesBlocking (statistics)OphthalmologyMedicineOptometryCapsulePosterior capsule opacificationPhacoemulsificationIntraocular lensVisual acuityComputer scienceBiology

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate intraindividual differences in posterior capsule opacification (PCO) and visual performance of AcrySof SN60AT (Alcon Laboratories) and AF-1 YA-60BB (Hoya Corp.) intraocular lenses (IOLs). SETTING: Ophthalmology Department, St. Thomas' Hospital, London, United Kingdom. METHODS: In this prospective single-surgeon standardized-surgical-procedure fellow-eye comparison, an AcrySof SN60AT or an AF-1 YA-60BB IOL was randomized to the first eye of 36 patients and fellow-eye surgery was performed within 4 to 6 weeks. Follow-up was at 1, 3, 6, 12, and 24 months. Best distance- corrected logMAR visual acuity was measured at 100% and 9% contrast. Contrast sensitivity was measured using the Functional Acuity Contrast Test (FACT) on the Optec 3500 instrument (Stereo Optical Company, Inc.). Color vision was assessed with the Farnsworth Munsell 100-hue test. After pupil dilation, digital retroillumination photographs were taken and the percentage area of PCO was calculated using POCO software. RESULTS: Posterior capsule opacification was significantly greater in the AF-1 YA-60BB group than in the AcrySof SN60AT group at all time points (P<.0001), with the difference greatest at 24 months. At 24 months, 100% contrast visual acuity was significantly better in the AcrySof SN60AT group than in the AF-1 YA-60BB group (P = .0313); 9% contrast visual acuity was significantly better in the AcrySof SN60AT group from 6 months onward. There was no significant difference between groups in color vision or contrast sensitivity. Electron microscopy showed the AcrySof SN60AT IOL has a much sharper posterior edge profile. CONCLUSIONS: The AcrySof SN60AT IOL had better PCO performance and thus visual performance than the AF-1 YA-60BB IOL. This is attributable to the differences in optic edge design.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.134
Threshold uncertainty score0.923

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.293
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cataract & Refractive SurgerySame topicIntraocular Surgery and LensesFrench-language works237,207