MétaCan
Menu
Back to cohort
Record W1989103032 · doi:10.1089/ars.2012.4714

Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine

2012· article· en· W1989103032 on OpenAlexaff
Lars Barregård, Peter Möller, Trine Henriksen, Vilas Mistry, Gudrun Koppen, Pavel Rössner, Radim J. Šrám, Allan Weimann, Henrik E. Poulsen, Robert Nataf, Roberta Andreoli, Paola Manini, Tim Marczylo, Patricia Lam, Mark D. Evans, Hiroshi Kasai, Kazuaki Kawai, Yun‐Shan Li, Kazuo Sakai, Rajinder Singh, Friederike Teichert, Peter B. Farmer, Rafał Różalski, Daniel Gackowski, Agnieszka Siomek, Guillermo T. Sáez, Concha Cerdá, Karin Bröberg, Christian Lindh, Mohammad Bakhtiar Hossain, Siamak Haghdoost, Chiung‐Wen Hu, Mu‐Rong Chao, Kuen‐Yuh Wu, Hi̇lmi̇ Orhan, N. Senduran, Raymond J. Smith, Regina M. Santella, Yali Su, Czarina Cortez, Susan Yeh, Ryszard Oliński, Steffen Loft, Marcus S. Cooke

Bibliographic record

VenueAntioxidants and Redox Signaling · 2012
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicDNA Repair Mechanisms
Canadian institutionsKronos (Canada)Institute of Aging
FundersNational Institute of Environmental Health SciencesEuropean Commission
KeywordsDeoxyguanosine8-Hydroxy-2'-deoxyguanosineUrinary systemChemistryEnvironmental chemistryChromatographyMedicineDNAInternal medicineBiochemistry

Abstract

fetched live from OpenAlex

AIMS: Urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. RESULTS: Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed 'spot' samples showed strong correlations with 24 h excretion (the 'gold' standard) of urinary 8-oxodG (rp 0.67-0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). INNOVATION: This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. CONCLUSION: ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.047
metaresearch head score (Gemma)0.050
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.047
Threshold uncertainty score0.247

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0470.050
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0020.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.052
GPT teacher head0.305
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations157
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueAntioxidants and Redox SignalingSame topicDNA Repair MechanismsFrench-language works237,207