MétaCan
Menu
Back to cohort
Record W1989114663 · doi:10.1016/s0736-0266(02)00198-5

Variability and repeatability of the flexion axis at the ulnohumeral joint

2003· article· en· W1989114663 on OpenAlexafffund
Teresa R. Duck, Cynthia E. Dunning, Graham J.W. King, James A. Johnson

Bibliographic record

VenueJournal of Orthopaedic Research® · 2003
Typearticle
Languageen
FieldMedicine
TopicElbow and Forearm Trauma Treatment
Canadian institutionsSt Joseph's Health CareWestern University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchShandong Academy of Sciences
KeywordsElbowForearmElbow flexionMedicineValgusOrthodonticsRepeatabilityAnatomyDisplacement (psychology)Knee flexionMathematicsPsychology

Abstract

fetched live from OpenAlex

Previous investigations have implemented screw displacement axes (SDAs) to define the elbow flexion axis for proper positioning of dynamic external fixators and endoprostheses. However, results across studies vary, which may be attributed to forearm position (pronation-supination) during elbow motion, or the mode of loading (active/passive) employed to generate flexion. Therefore, the aim of this study was to determine the influence of the flexion mode employed and forearm position on individual variation and repeatability of SDAs throughout elbow flexion. With the forearm pronated, the location of the average SDA was similar whether elbow flexion was generated actively or passively. In contrast, with the forearm supinated, the average SDA was 2.4 degrees and 1.4 degrees more valgus (p<0.001) and internally rotated (p<0.001), respectively, and positioned 1.6 and 0.8 mm further proximally (p=0.002) and anteriorly (p=0.005) relative to the capitellum, respectively, during active compared to passive flexion. During active flexion, the location of the average SDA was independent of forearm position. Conversely, during passive flexion, the average SDA angle was 3.4 degrees and 1.0 degrees more valgus (p<0.001) and internally rotated (p=0.009), respectively, and 1.7 and 0.7 mm more proximal (p<0.001) and anterior (p=0.001) relative to the capitellum, respectively, with the forearm held pronated rather than supinated. SDAs calculated throughout flexion deviated from the average SDA in both orientation and position, demonstrating that elbow flexion behaves similar to a loose hinge joint. These factors suggest that to encompass the location of all SDAs throughout flexion, and therefore properly mimic normal elbow joint motion, an endoprosthesis should be modeled similar to a "loose" rather than "pure" hinge joint. This would allow for dependencies of SDA angulation on forearm position and muscle activation, and slight freedom of movement to account for variances in SDA location. These factors should also be considered during soft-tissue reconstructions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.013
Threshold uncertainty score0.407

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0110.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.081
GPT teacher head0.355
Teacher spread0.274 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations55
Published2003
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Orthopaedic Research®Same topicElbow and Forearm Trauma TreatmentFrench-language works237,207