Record W1989303703 · doi:10.1118/1.4895003

Effect of improved TLD dosimetry on the determination of dose rate constants for <sup>125</sup>I and <sup>103</sup>Pd brachytherapy seeds

2014· article· en· W1989303703 on OpenAlexafffund
D. W. O. Rogers

Bibliographic record

VenueMedical Physics · 2014
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsCarleton UniversityPrincess Margaret Cancer Centre
FundersCedars-Sinai Medical CenterNatural Sciences and Engineering Research Council of CanadaMcGill University
KeywordsMonte Carlo methodDosimetryThermoluminescent dosimeterBrachytherapyAbsorbed doseImaging phantomPhysicsPercentage depth dose curveNuclear medicineThermoluminescenceComputational physicsMaterials scienceAtomic physicsNuclear physicsDosimeterIrradiationIonization chamberMathematicsOpticsStatisticsIonRadiation therapyMedicine

Abstract

fetched live from OpenAlex

PURPOSE: To more accurately account for the relative intrinsic energy dependence and relative absorbed-dose energy dependence of TLDs when used to measure dose rate constants (DRCs) for (125)I and (103)Pd brachytherapy seeds, to thereby establish revised "measured values" for all seeds and compare the revised values with Monte Carlo and consensus values. METHODS: The relative absorbed-dose energy dependence, f(rel), for TLDs and the phantom correction, Pphant, are calculated for (125)I and (103)Pd seeds using the EGSnrc BrachyDose and DOSXYZnrc codes. The original energy dependence and phantom corrections applied to DRC measurements are replaced by calculated (f(rel))(-1) and Pphant values for 24 different seed models. By comparing the modified measured DRCs to the MC values, an appropriate relative intrinsic energy dependence, kbq (rel), is determined. The new Pphant values and relative absorbed-dose sensitivities, SAD (rel), calculated as the product of (f(rel))(-1) and (kbq (rel))(-1), are used to individually revise the measured DRCs for comparison with Monte Carlo calculated values and TG-43U1 or TG-43U1S1 consensus values. RESULTS: In general, f(rel) is sensitive to the energy spectra and models of the brachytherapy seeds. Values may vary up to 8.4% among (125)I and (103)Pd seed models and common TLD shapes. Pphant values depend primarily on the isotope used. Deduced (kbq (rel))(-1) values are 1.074 ± 0.015 and 1.084 ± 0.026 for (125)I and (103)Pd seeds, respectively. For (1 mm)(3) chips, this implies an overall absorbed-dose sensitivity relative to (60)Co or 6 MV calibrations of 1.51 ± 1% and 1.47 ± 2% for (125)I and (103)Pd seeds, respectively, as opposed to the widely used value of 1.41. Values of Pphant calculated here have much lower statistical uncertainties than literature values, but systematic uncertainties from density and composition uncertainties are significant. Using these revised values with the literature's DRC measurements, the average discrepancies between revised measured values and Monte Carlo values are 1.2% and 0.2% for (125)I and (103)Pd seeds, respectively, compared to average discrepancies for the original measured values of 4.8%. On average, the revised measured values are 4.3% and 5.9% lower than the original measured values for (103)Pd and (125)I seeds, respectively. The average of revised DRCs and Monte Carlo values is 3.8% and 2.8% lower for (125)I and (103)Pd seeds, respectively, than the consensus values in TG-43U1 or TG-43U1S1. CONCLUSIONS: This work shows that f(rel) is TLD shape and seed model dependent suggesting a need to update the generalized energy response dependence, i.e., relative absorbed-dose sensitivity, measured 25 years ago and applied often to DRC measurements of (125)I and (103)Pd brachytherapy seeds. The intrinsic energy dependence for LiF TLDs deduced here is consistent with previous dosimetry studies and emphasizes the need to revise the DRC consensus values reported by TG-43U1 or TG-43U1S1.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.009
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.009
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.279
Teacher spread0.273 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207