MétaCan
Menu
← Back to cohort
Record W1989305678 · doi:10.1118/1.3612510

SU-E-T-548: Retrospective Evaluation of Stereotactic Radiosurgery Plans at the Tom Baker Cancer Centre

2011· article· en· W1989305678 on OpenAlexaff
Julia Stanley, Peter Dunscombe, David P. Spencer

Bibliographic record

VenueMedical Physics · 2011
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsConformityRadiosurgeryNuclear medicineMedicineVolume (thermodynamics)DosimetryIndex (typography)Radiation therapySurgeryPsychologyComputer science

Abstract

fetched live from OpenAlex

Purpose: This study summarizes the stereotactic radiosurgery (SRS) plans created over a period of five years. Additionally, factors that influenced the Radiation Therapy Oncology Group (RTOG) conformity indices of the plans were determined. Methods: A database of 170 SRS plans for brain metastases patients treated at the Tom Baker Cancer Centre using dynamic conformal arcs between November 2004 and December 2009 was constructed. This database was then used to retrospectively evaluate SRS plans and to determine target parameters that affect RTOG conformity index which is defined by CI= VRI/TV where VRI is the volume that receives the reference isodose and TV is the target volume. Results: Factors such as maximum dose to the target and minimum dose to the target did not appear to influence RTOG conformity index. However, target volume did relate to RTOG conformity index: conformity index increased as target volume decreased. For the 101 plans with target volumes larger than 1cm3 the average conformity index value was 1.68. For plans with target volumes smaller than 1cm3 the average conformity index value was 2.41. Additionally, a decrease in RTOG conformity index was correlated with a decrease in the volume of normal tissue receiving the prescription isodose. For plans where the volume of normal tissue receiving the prescription isodose was less than 1 cm3 the average RTOG conformity index was 1.32 while for plans where the volume of normal tissue receiving the prescription isodose was greater than 1 cm3 the average RTOG conformity index was 2.36 Conclusions: 170 SRS plans for brain metastases were evaluated and it was found that RTOG conformity index was influenced by target size and could be linked to the volume of non target tissue receiving the prescription isodose

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.983
Threshold uncertainty score0.035

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.306
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→