Abstract

fetched live from OpenAlex

INTRODUCTION: Radiofrequency (RF) and cryoenergy are largely considered independent modalities for the transcatheter ablation of cardiac arrhythmias. There are numerous theoretical advantages to engineering a system capable of delivering both energy forms. METHODS AND RESULTS: We designed a hybrid steerable catheter capable of delivering RF and cryoenergy independently, sequentially, and simultaneously. The novel catheter system was tested pre-clinically by creating a total of 180 ablation lesions in 20 mongrel dogs. Right atrial and right and left ventricular sites were preselected by a randomized factorial design devised to compare sequential and simultaneous RF and cryoenergy applications to standard RF, irrigated RF, and standard cryoablation. A steerable 4-mm electrode-tip hybrid catheter ("Fire and Ice") was created by modifying a 7 F cryocatheter (Freezor, CryoCath Technologies, Montreal, Canada). RF energy was injected via a copper wire, thermocouples were isolated to reduce RF interference, and 100 KHz band pass filters and RF chokes were added. Sequential low-dose RF (20 W, 60 seconds) preceding or following cryoablation resulted in larger lesions (P = 0.0010). The addition of RF energy did, however, produce more thrombus than cryoenergy alone, with clot detected on 82.4% versus 12.1% of ablation lesions, P < 0.0001. Simultaneously applying the two energy modalities (45 W, 10 or 30 degrees C, 60 seconds) created more voluminous lesions than standard RF ablation (median 288.1 vs 126.1 mm(3), P = 0.0333) of similar dimension to irrigated RF ablation. CONCLUSION: A versatile catheter system was fashioned capable of creating standard cryoablation lesions, standard RF lesions, and simultaneous lesions of similar dimension to irrigated RF.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.528
Threshold uncertainty score0.561

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.221
Teacher spread0.212 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2007
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ElectrophysiologySame topicCardiac Arrhythmias and TreatmentsFrench-language works237,207