MétaCan
Menu
Back to cohort
Record W1989701078 · doi:10.1002/jor.21282

Growth plate explants respond differently to in vitro static and dynamic loadings

2010· article· en· W1989701078 on OpenAlexaff
Kim Sergerie, Stefan Parent, Pierre-François Beauchemin, Irene Londoño, Florina Moldovan, Isabelle Villemure

Bibliographic record

VenueJournal of Orthopaedic Research® · 2010
Typearticle
Languageen
FieldMedicine
TopicTendon Structure and Treatment
Canadian institutionsUniversité de MontréalPolytechnique MontréalCentre Hospitalier Universitaire Sainte-Justine
Fundersnot available
KeywordsAggrecanExtracellular matrixType I collagenMatrix (chemical analysis)Explant cultureType II collagenIn vitroMaterials scienceCompression (physics)Biomedical engineeringChemistryBiophysicsComposite materialAnatomyBiologyPathologyBiochemistryEndocrinologyCartilageMedicine

Abstract

fetched live from OpenAlex

This study aimed at investigating the effects of static and dynamic compression applied on growth plate explants using matched compressive strains. Growth plate explants from 4-week-old swine ulnae were submitted to in vitro static (10% strain) or dynamic (oscillating between 7% and 13% at 0.1 Hz) unconfined compression for 48 h. The total growth plate height, the combined proliferative and hypertrophic thickness and the resulting ratio between these two thicknesses were evaluated. Standard immunohistochemistry was used to analyze the protein expression of key components of the extracellular matrix: aggrecan, type II collagen, type X collagen, and MMP13. In the statically loaded samples, the columnar organization of the cells was preserved but with slight columns deviation from the growth axis. Decreases in all histomorphological parameters were important and a notable loss of aggrecan, type II and type X collagens expressions was denoted. In the dynamically loaded samples, a severe loss of columnar arrangement was observed in the proliferative and hypertrophic zones. However, dynamic compressive loads preserved the proliferative and hypertrophic zones ratio and contributed to the synthesis of aggrecan and type II collagen in the extracellular matrix. The exact response of the growth plate to mechanical stresses along with optimal loading parameters could help improve the current treatment approaches or develop new treatment approaches for the underlying progressive musculoskeletal deformities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.754
Threshold uncertainty score0.515

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.364
Teacher spread0.337 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations37
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Orthopaedic Research®Same topicTendon Structure and TreatmentFrench-language works237,207