MétaCan
Menu
Back to cohort

Does Anterolateral Cage Insertion Enhance Immediate Stabilization of the Functional Spinal Unit?

2001· article· en· W1991807146 on OpenAlexaff
Thomas Nydegger, Thomas R. Oxland, Zoltán Hoffer, William Cottle, Lutz-P. Nolte

Bibliographic record

VenueSpine · 2001
Typearticle
Languageen
FieldMedicine
TopicSpine and Intervertebral Disc Pathology
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsMedicineCageUnit (ring theory)Physical medicine and rehabilitation

Abstract

fetched live from OpenAlex

STUDY DESIGN: The three-dimensional flexibility of six human lumbar functional spinal units was measured after the anterolateral insertion of an interbody cage. OBJECTIVES: To determine whether an interbody cage inserted from an anterolateral direction stabilizes the spine with respect to the intact state and to compare the finding with that from the same cage inserted from an anterior direction. SUMMARY OF BACKGROUND DATA: Several biomechanical studies have shown that interbody cages do not stabilize the spine in extension. It is suspected that this may be caused by the destruction of the anterior longitudinal ligament and anterior anulus fibrosus. METHODS: Six human cadaveric lumbar functional spinal units were tested under pure moments of flexion, extension, bilateral axial rotation, and bilateral lateral bending to a maximum of 10 Nm. The relative intervertebral motions were measured by an optoelectronic camera system with the spinal units in the intact condition, after discectomy, after anterolateral interbody cage stabilization, and with additional translaminar screw fixation. The implant used was a central, porous, contoured implant with endplate fit. The results were compared with those of a previous study, which used the same implant inserted from an anterior direction. RESULTS: The anterolateral cage insertion significantly decreased the motion in comparison with the intact situation in flexion and lateral bending, but not in extension or axial rotation. No differences were found between the anterior and anterolateral insertion approaches in flexion or extension, but differences were observed in axial rotation and lateral bending, in which the anterolateral approach resulted in more motion. Additional translaminar screw fixation reduced motion to below intact levels in all loading directions. None of the surgical procedures introduced asymmetrical behavior. CONCLUSIONS: Anterolateral cage insertion did not stabilize the spine in extension or axial rotation and was not different from the anterior approach in flexion and extension. Additional translaminar screw fixation stabilized in all directions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.292
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2001
Admission routes1
Has abstractyes

Explore more