MétaCan
Menu
Back to cohort
Record W1992083411 · doi:10.1081/bio-120003194

THE EFFECTS OF HEMODILUTION WITH HEMOLINK™ UPON HEMODYNAMICS AND BLOOD FLOW DISTRIBUTION IN ANESTHETIZED DOGS<sup>*</sup>

2002· article· en· W1992083411 on OpenAlexaff
John G. Kingma, Reena Sandhu, N Hamelin, Daniel Gendron, Yannick Trudel, Marco Bosa, Richard K. Stewart, M. B. Fargey, George P. Biro

Bibliographic record

VenueArtificial Cells Blood Substitutes and Biotechnology · 2002
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicHemoglobin structure and function
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsHematocritBeagleHemodynamicsHemoglobinCardiac outputBlood volumeBlood flowMedicineExchange transfusionVascular resistanceAnesthesiaChemistryInternal medicineCardiology

Abstract

fetched live from OpenAlex

Hemoglobin based oxygen-carrying solutions (HBOCs) as hemoglobin replacement therapeutics are being tested for clinical use. Some of these products are associated with elevations in both systemic and pulmonary vascular resistances but their effect on the distribution of blood flow to major organs in larger animals have not been extensively described. We tested two formulations of o-raffinose cross-linked human hemoglobin, Hemolink (frozen-Hemolink-1 and refrigerated Hemolink-2) and compared them to Pentaspan, a colloid volume expander in extensive clinical use. Cardiovascular measurements and the distribution of blood flow (radionuclide-labeled microspheres) to the major organs were determined in Beagle dogs (n = 5 per group). After baseline measurements, either Hemolink-1, Hemolink-2, or Pentaspan was exchange transfused in an isovolemic manner (resulting in hematocrit reduction to approximately 20-25%); measurements were made 30, 60, 120 and 180 min post-exchange. There was no significant difference in cardiac output, mean arterial pressures and systemic or pulmonary vascular resistances after exchange in any of the three groups. Myocardial blood flow increased in all three groups post-exchange but the increase was more sustained in the Hemolink groups. Endocardial/epicardial flow ratios were also maintained after exchange in all groups. Thus, Hemolink is ideally suited for volume replacement when used in conjunction with acute normovolemic hemodilution because under these circumstances, the adverse hemodynamic effects are alleviated while extra hemoglobin is added to the blood.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.003
GPT teacher head0.169
Teacher spread0.166 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2002
Admission routes1
Has abstractyes

Explore more

Same venueArtificial Cells Blood Substitutes and BiotechnologySame topicHemoglobin structure and functionFrench-language works237,207