MétaCan
Menu
Back to cohort
Record W1992083411 · doi:10.1081/bio-120003194

THE EFFECTS OF HEMODILUTION WITH HEMOLINK™ UPON HEMODYNAMICS AND BLOOD FLOW DISTRIBUTION IN ANESTHETIZED DOGS<sup>*</sup>

2002· article· en· W1992083411 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueArtificial Cells Blood Substitutes and Biotechnology · 2002
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicHemoglobin structure and function
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsHematocritBeagleHemodynamicsHemoglobinCardiac outputBlood volumeBlood flowMedicineExchange transfusionVascular resistanceAnesthesiaChemistryInternal medicineCardiology

Abstract

fetched live from OpenAlex

Hemoglobin based oxygen-carrying solutions (HBOCs) as hemoglobin replacement therapeutics are being tested for clinical use. Some of these products are associated with elevations in both systemic and pulmonary vascular resistances but their effect on the distribution of blood flow to major organs in larger animals have not been extensively described. We tested two formulations of o-raffinose cross-linked human hemoglobin, Hemolink (frozen-Hemolink-1 and refrigerated Hemolink-2) and compared them to Pentaspan, a colloid volume expander in extensive clinical use. Cardiovascular measurements and the distribution of blood flow (radionuclide-labeled microspheres) to the major organs were determined in Beagle dogs (n = 5 per group). After baseline measurements, either Hemolink-1, Hemolink-2, or Pentaspan was exchange transfused in an isovolemic manner (resulting in hematocrit reduction to approximately 20-25%); measurements were made 30, 60, 120 and 180 min post-exchange. There was no significant difference in cardiac output, mean arterial pressures and systemic or pulmonary vascular resistances after exchange in any of the three groups. Myocardial blood flow increased in all three groups post-exchange but the increase was more sustained in the Hemolink groups. Endocardial/epicardial flow ratios were also maintained after exchange in all groups. Thus, Hemolink is ideally suited for volume replacement when used in conjunction with acute normovolemic hemodilution because under these circumstances, the adverse hemodynamic effects are alleviated while extra hemoglobin is added to the blood.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.027
Threshold uncertainty score0.568

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.003
GPT teacher head0.169
Teacher spread0.166 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it